Number
Size (Bytes)
Default Value
Name
Description
17
1
1
Inverse Water Valve Report
Inverses Switch Binary Report when Water Valve = 0x00 “Valve doesn’t let the water run through in Notification and real physical status.”
18
1
1
Association Group 2 SET Value
Configure Association Group 2 Basic Set value when Binary Switch Report = 0xFF *(Related to Configuration setting 0x11)
19
1
2
Association Group 2 SET Value
Configure Association Group 2 Basic Set value when Binary Switch Report = 0x00 *(Related to Configuration setting 0x11)
33
1
1
Temperature Report Unit
Configure Temperature Unit report. The default Unit is depended on Regional Frequency Setting. (By default, US=°F and EU=°C)
34
2
260
Temperature Threshold Change
Configure Temperature threshold changed and send auto report
35
2
256
Temperature Report Offset
Configure Temperature Offset degree; Higher byte 0x = Positive degree and 1x= Negative degree.
36
2
360
Overheat Trigger Value
Configure Overheat report trigger value. “Higher byte 0x00 represents Celsius °C unit, 0x01 represents Fahrenheit °F unit
37
2
342
Overheat Recover value
Configure Overheat Recover report value
38
1
0
Association Group 4 Overheat Trigger
Configure Overheat Trigger Value in Association Group 4
39
1
0
Association Group 4 Overheat Cancel
Configure Overheat Cancellation SET value
40
2
288
Freeze Trigger Value
Configure Freeze Trigger Report value
41
2
292
Freeze Recover Value
Configure Freeze Recover Report Value
42
1
1
Freeze Detection Valve Control
Enable / Disable Valve Control during Freeze when Water Leak is detected “Detected by built-in temperature sensor.
Refer to Configuration CC parameter 0x28 (41) & 0x29 (42)
43
1
0
Association Group 5 Freeze Trigger
Configure Association Group 5 Freeze Detection Trigger Basic Set value
44
1
0
Association Group 5 Freeze Cancel
Configure Association Group 5 Freeze Detection Cancellation Basic Set value
49
1
1
Association Group 3 Water Leak Trigger
Configure Association Group 3 Water Leak Trigger Basic Set value
50
1
0
Association Group 3 Water Leak Cancel
Configure Association Group Water Leak Cancellation Basic Set value
51
1
1
Water Leak Detection Valve Control
Disable / Enable Valve Control when Water Leak detected
65
1
1
Buzzer
Enable / Disable Built-in Buzzer Sound
66
1
80
LED Brightness Level
Configure Built-in LED Brightness Level
67
1
0
Touch Keylock Protection
Disable / Enable Touch Keylock Protection
81
1
13
Notification Report
Configure Notification Report in Association Group 1 Lifeline “Set Bit to 0 = Disable, Set Bit to 1 = Enable”
Default value 0x0D (13)
Only available values as below
xxxx xxx0 = Disable to report valve Open / Close status
xxxx xxx1 = Enable to report valve Open / Close status (Default)
xxxx xx0x = Disable Overheat Detection (Default)
xxxx xx1x = Enable Overheat Detection
xxxx x0xx = Disable Freeze (Underheat) Detection
xxxx x1xx = Enable Freeze (Underheat) Detection (Default)
xxxx 0xxx = Disable Water Leak Detection
xxxx 1xxx = Enable Water Leak Detection (Default)