Original replacement thionyl chloride lithium battery for Fluidra's Blue Connect Smart Water Analyzer.
Approximate dimensions: 13 x 1.5 x 1.5 cm
The battery has to be replaced approximately every two years under normal use conditions.
To ensure maximum battery life, Poolaria recommends putting the Blue Connect into standby mode when your pool is in hibernation (see the instruction manual for more information).
Steps to follow to replace the battery:
In "Parameters" »" Blue Connect ", tap" Battery change ".
Take the analyzer out of the water, remove the rubber ring and the use cap and place Blue Connect in the storage cap.
Dry it and start the procedure in a clean, dry place.
Remove the adhesive tape and unscrew the top of the device. This is a left hand thread. Unscrew clockwise. Remove the gasket and discard it.
Disconnect the white connector by pulling on the red and black cable. The battery is at the other end of the cable. Press down on the plastic rod to release the battery and remove it by pulling on the cable.
Place the battery in the bottom of the cavity until it locks. Then connect the connector.
Place the new gasket supplied with the battery into the thread on the top of the unit. Close the top. This is a left hand thread. Screw it counterclockwise.
Stick the new adhesive tape supplied with the battery and put the ring back on. Next, put the use cap on and put your Blue Connect back in the water.