Viewed products





Confianza Online


domoticalia.es/es/ Reviews with ekomi.es

Qubino Flush Shutter DC

ZMNHOD1

New

Qubino Flush Shutter DC Micromodule for controlling blinds, curtains, venetian blinds, awnings, garage doors, etc. with the ability to reverse the polarity to drive 12-24VDC (direct current) motors for this type of shutter home automation applications, its "shutter" or other door / window concealments based on inverted motors.

More details

In Stock

62,30 €

-12%

70,80 €

Technical characteristics

Home Automation Technology Z-Wave Plus
Characteristic Consumption Measurement

More info

The only Z-Wave shutter controller in the world, for direct current (DC) motors

The Qubino Flush Shutter DC micromodule for "sealing" / concealment of Qubino, is ideal for controlling 12-24V DC motors of blinds, rollers, curtains and blinds, Venetian blinds, awnings and similar sunscreens, as well as door openers. garage. You can control it remotely through the Z-Wave network or through wall switches. It also measures the energy consumption of the connected motor or turning device and supports the connection of a digital temperature sensor.

The smallest Z-Wave blind control module of all

The micromodule or "tablet" for the control of blinds Qubino Flush Shutter DC is the smallest module of Z-Wave in the world because it occupies a smaller volume than comparable modules of any other brand and will fit easily in any box of mechanisms embedded.

Qubino Flush Shutter DC direct current

What is it for?

The Qubino Flush Shutter DC micromodule for Z-Wave blind control is ideal for remotely controlling 12-24V DC motors of blinds, pulleys, blinds, awnings, garage doors, Venetian blinds and similar sunscreens.

New functionality for Venetian blinds tilting slats

Video to see it in action:

Energy control

The Z-Wave micromodule Qubino Flush Shutter DC , for the control of venetian blinds and blinds, among other concealment systems, measures the electrical consumption of the electrical device or the rotary / displacement motor connected and of itself, when it is in "standby" "it only consumes 0.3 W.

Very versatile

The Qubino Flush Shutter DC , can operate through a wide range of temperatures from cold -10ÚC to suffocating 40ÚC (14Ú 104ÚF). It supports the connection of a digital temperature sensor, which is also useful for creating complex scenarios. Each module also acts as a repeater in order to improve the range and stability of the Z-Wave network.

The simplest installation.

The extremely small size and a specially designed housing mean that the connection of the module inside a recessed mounting box is simple. The installation process, tested and approved by professional electricians , consists of only three simple steps:

1 - Remove the switches from the box and disconnect the cables.
2 - Connect the cables to the Qubino module and insert them into the box.
3 - Fix the switches to the box.

The most proven and reliable Z-Wave modules

Qubino's Z-Wave modules are install-and-forget products. The Qubino products that we offer, are manufactured to last, so they only use electronic components that meet the most demanding levels of quality. Our modules are also the most tested Z-Wave micromodules on the market. The Slovenian Institute of Quality and Measurement (SIQ), an independent European entity, checks the quality of the actual parameters of our products, including temperature increases, manufacturing, insulation resistance, electrical consumption and overloads according to European standards of the highest quality according to the specification of standard EN 60669-2-1.

Additional parameters for professionals.

The Qubino Flush Shutter DC micromodule   It has 14 additional parameters for its use by experts. Some of the most useful are:

  • Activate / deactivate functions ALL ON / ALL OFF
  • Define the selection between two available operating modes
  • Define the time needed for the slats to complete full turn (180 degrees)

Technical specifications and electrical diagrams:

Qubino Flush Shutter DC connection scheme

Feeding: 12 24 VDC ± 10%

Rated load current

2 A
Protection against overload 5 A
Output power of the DC output (resistive load) 48 W (24 VDC)
Output circuit power of DC output (resistive load): 5 A
Accuracy of the power measurement: +/- 5%
Digital temperature sensor range: -50 ° ~ + 125 ° C, resolution 0.1 ° C
Cable length of the digital temperature sensor: 1000 mm
Operating Temperature: -10 ° ~ + 40 ° C
Distance up to 30 m indoors (depending on materials)
Dimensions (WxHxD) 41.8 x 36.8 x 15.4 mm
(packaging) (115 x 96 x 22)
Weight (including packaging) 28 g (34 g)
Electric consumption on standby 0.3 W
For installation in mechanism boxes Ø e 60 mm or 2 M
Switching by: "H bridge"

Meets CE and ROHS Certifications

Extended Z-Wave info

Name: Flush Shutter DC
Manufacturer:QUBINO
Identifier:ZMNHOD1
Z-Wave Certification Number:ZC10-17085744
Hardware Plattform:ZM5202
FLiRS:NO
Role Type:Always On Slave
Short Description:The Qubino Flush Shutter DC is ideal for controlling the 12–24V DC motors of blinds, rollers, shades, venetian blinds and similar sunscreens.
Description:The Qubino Flush Shutter DC is ideal for controlling the 12–24V DC motors of blinds, rollers, shades, venetian blinds and similar sunscreens. You can control it either remotely through the Z-Wave network or through wall switches. It also measures power consumption and supports the connection of a digital temperature sensor.

Manual download HERE.

Group
Max Nodes
Description
1
5
Z-Wave Plus Lifeline
2
15
Basic on/off (triggered at change of the input I1 state and reflecting its state)
3
16
Basic on/off (triggered at change of the input I2 state and reflecting its state)
4
16
Basic on/off (triggered at sensing moving direction of roller: up=FF, down=0)
5
16
Basic on/off (triggered at reaching roller position: bottom=FF, top=0)
6
16
Basic on/off (triggered at reaching roller position: bottom=FF, not bottom=0)
7
16
Multilevel set (triggered at changes of value of the Flush Shutter DC position)
8
16
Multilevel set (triggered at changes of value of slats tilting position)
9
16
Multilevel sensor report (triggered at change of temperature sensor
Number
Size (Bytes)
Default Value
Name
Description
10
2
255
Activate/deactivate functions ALL ON / ALL OFF
Flush Shutter DCs module responds to commands ALL ON / ALL OFF that may be sent by the primary or secondary controller within the Z-Wave network.
110
2
32536
Temperature sensor offset settings
Set value is added to or subtracted from the actually measured value to adjust the temperature report sent by an external sensor (sold separately). This parameter only applies to the degrees temperature unit (the Fahrenheit unit is currently not supported).
120
1
5
Temperature sensor reporting
If an external digital temperature sensor (sold separately) is connected to the module, it reports temperature readings based on the threshold defined in this parameter. This parameter only applies to the degrees temperature unit (the Fahrenheit unit is currently not supported).
250
1
0
Unsecure / Secure Inclusion
A Flush Shutter DC supports secure and unsecure inclusion. Even if the controller does not support security command classes, a dimmer could be included as unsecure and keep all the functionality. In case of an overload, the device will send an overload notification(COMMAND_CLASS_NOTIFICATION_V5) towards the controller with the "Notification type" field set to 0x08 (POWER MANAGEMENT) and the "Event" field set to 0x08 ("Over load detected").
40
1
10
Power reporting in Watts on power change for Q1 or Q2
Choose by how much power consumption needs to increase or decrease to be reported. Values correspond to percentages so if 10 is set (by default), the module will report any power consumption changes of 10% or more compared to the last reading. NOTE: Power consumption needs to increase or decrease by at least 1 Watt to be reported, REGARDLESS of percentage set in this parameter.
42
2
0
Power reporting in Watts by time interval for Q1 or Q2
The set value refers to the time interval with which the power consumption in Watts is reported (0 – 32767 seconds). If 0 is entered (by default), energy consumption reports will not be sent to the controller.
71
1
0
Operating modes
Choose between the two operating modes. If the venetian mode is selected, an additional widget/endpoint will be displayed on the UI interface, which can be used to control the tilt position of the slats. If the Shutter mode is selected, this additional endpoint is hidden. NOTE1: After the value of this parameter is changed, first exclude module (without setting parameters to their default values), wait at least 30s and then reinclude the module!
72
2
150
Slats tilting full turn time
Set the time, required by the slats, to make a full turn (180 degrees). NOTE: If the set time is too long and a full turn was already performed, the device will start to move up or down for the remaining time.
73
1
1
Slats position
Choose the position of the slats after up/down movement (activated through the Z-Wave controller or the push-buttons) is completed.
74
2
0
Motor moving up/down time
This parameter defines the time, required by the Shutter DC motor, to completely open or completely close the attached shutters. After the set time passes, the motor stops (relay goes to the off state). NOTE: It is important that the reference position, for setting the moving time, is always when the Shutter is at its lowest position! Set parameter 74 to 0 and move the Shutter (using the up/down push-buttons or the main controller UI) to the lowest desired position. When the Shutter reaches this position, set the parameter 74 to the duration, required by the Shutter, to completely open or completely close the attached shutters. At this point the Shutter can be moved up (open), but can't be moved down, because this position is already set as its lowest position. To change the defined lowest position of the Shutter below the one, which is already defined (manual recalibration), the parameter 74 must be set to 0 and the procedure, which is described above, should be repeated. In case the Shutter operates using limit switches, but the user still wants to control the opening/closing position with time, this is still possible. If a time duration, which is longer than the opening/closing time of the shutters in real time (limited by the limit switches), is set, the Shutter will stop at the limit switches, but the module relay will switch it off after a defined time, not by the limit switch of the Shutter. Take into consideration that in this condition, positioning the shutters with the slider (through the UI) will not display the correct position of the Shutter.
76
1
6
Motor operation detection
Define the power consumption threshold at the end positions. Based on this value, the device will know, that the shutters reached the limit switches.
78
1
0
Forced Shutter DC calibration
By changing the value of this parameter from 0 to 1, the Shutter enters the calibration mode. For further information about the calibration process, please see section 9.
85
1
8
Power consumption max delay time
Define the maximum time before the power consumption of the motor, after one of the relays is switched ON, is read from the device. If there is no power consumption during the set time (motor not connected, damaged or requires longer time to start, motor at the end position), the relay will switch OFF. This time is defined by entering it manually.
86
1
8
Power consumption at limit switch delay time
This parameter defines the maximum time after which the active output will switch off, due to reaching a limit switch. When power consumption is below the specified power threshold, defined in the parameter no. 76, the set time duration will have to pass in order for the output to turn off.
90
1
5
Time delay for next motor movement
This parameter defines the minimum time duration between successive motor movements (minimum time after which the motor is switched off and on again).
Basic
COMMAND_CLASS_BASIC
Notification V5
COMMAND_CLASS_NOTIFICATION_V5
Switch Multilevel V3
COMMAND_CLASS_SWITCH_MULTILEVEL_V3
Association Group Information V2
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V2
Association V2
COMMAND_CLASS_ASSOCIATION_V2
Basic
COMMAND_CLASS_BASIC
Configuration
COMMAND_CLASS_CONFIGURATION
Device Reset Locally
COMMAND_CLASS_DEVICE_RESET_LOCALLY
Manufacturer Specific V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
Meter V4
COMMAND_CLASS_METER_V4
Multi-Channel Association V3
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3
Multi-Channel V4
COMMAND_CLASS_MULTI_CHANNEL_V4
Notification V5
COMMAND_CLASS_NOTIFICATION_V5
Powerlevel
COMMAND_CLASS_POWERLEVEL
Security S0
COMMAND_CLASS_SECURITY
Sensor Multilevel V7
COMMAND_CLASS_SENSOR_MULTILEVEL_V7
Switch All
COMMAND_CLASS_SWITCH_ALL
Switch Binary
COMMAND_CLASS_SWITCH_BINARY
Switch Multilevel V3
COMMAND_CLASS_SWITCH_MULTILEVEL_V3
Version V2
COMMAND_CLASS_VERSION_V2
Z-Wave Plus Info V2
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
Inclusion
• Connect module to power supply (with

temperature sensor connected - if purchased),

• auto-inclusion (works for about 5 seconds after connected to power supply) or

• press service button S for more than 2 second or

• press push button I1 three times within 3s (3 times change switch state within 3 seconds).



NOTE1: For auto-inclusion procedure, first set main controller into inclusion mode and then connect module to power supply.



NOTE2: When connecting temperature sensor to module that has already been included, you have to exclude module first. Switch off power supply, connect the sensor and re-include the module.

Exclusion
• Connect module to power supply

• bring module within maximum 1 meter (3 feet) of the main controller,

• enable add/remove mode on main controller,

• press service button S for more than 6 second or

• press push button I1 five times within 3s (5 times change switch state within 3 seconds) in the first 60 seconds after the module is connected to the power supply.

By this function all parameters of the module are set to default values and own ID is deleted.

If service button S is pressed more than 2 and less than 6 seconds (or if push button I1 is pressed three times within 3s) module is excluded, but configuration parameters are not set to default values.



NOTE: If the module is included with parameters 71 with value different to default and module reset is done, wait at least 30s before next inclusion.



NOTE: Please use this procedure only when the network primary controller is missing or otherwise inoperable.

Factory Reset
press service button S for more than 6 second or

• press push button I1 five times within 3s (5 times change switch state within 3 seconds) in the first 60 seconds after the module is connected to the power supply.

By this function all parameters of the module are set to default values and own ID is deleted.

If service button S is pressed more than 2 and less than 6 seconds (or if push button I1 is pressed three times within 3s) module is excluded, but configuration parameters are not set to default values.



NOTE: Please use this procedure only when the network primary controller is missing or otherwise inoperable.



Sensors
Sensor types supported by the product.
Color
If the product is only available in one color, pick the color from the list.
Window Covering Control Features
Select the feature(s) supported in the Window Covering Control product.
Supported Notification Types
Select the Notification Types that the product handles (controllers), or sends (slaves).
Supported Meter Type
Indicate which type of metering is supported by the device.

 

Reviews

Grade 
10/27/2021

Unico rele z-wave 24V DC

Estoy absolutamente encantado con el artículo. Hay otros relés Z-Wave pero yo necesitaba específicamente un relé de 24V DC. Hice una búsqueda a conciencia en internet y no creo que haya otro dispositivo en el planeta que hubiera resuelto mi problema.

Write your review!

Write a review

Qubino Flush Shutter DC

Qubino Flush Shutter DC

Qubino Flush Shutter DC Micromodule for controlling blinds, curtains, venetian blinds, awnings, garage doors, etc. with the ability to reverse the polarity to drive 12-24VDC (direct current) motors for this type of shutter home automation applications, its "shutter" or other door / window concealments based on inverted motors.

Accessories

11 other products in the same category:

Customers who bought this product also bought: