Technical characteristics

Home Automation Technology Z-Wave Plus
Characteristic Consumption Measurement

More info

The smallest Z-Wave double relay in the world

The Qubino Flush 2 Relays is ideal as a switch or double electric relay for lights, fans, ovens, washing machines, irons, sockets, garage doors, electric radiators, water heaters, etc.

The Qubino Flush 2 Relays module is ideal for switching on or off two electrical appliances or 2 independent electrical loads. You can control it remotely through the Z-Wave network or through wall switches. It also measures the power consumption of two electrical devices and supports the connection of a digital temperature sensor.

The smallest Z-Wave relay

The relay Z-Wave Qubino Flush 2 Relays is a micromodule that occupies less space than any other module with which it is compared to any other competitor and will fit easily into any conventional mechanism box.

Qubino Flush 2 Relay

This Z-Wave micromodule Qubino Flush 2 Relays   It is a double relay used to turn on or off (On / Off - all / nothing) electrical devices such as lights, fans, ovens, washing machines, irons, power outlets, garage doors, electric radiators, water heaters, etc. .

Eye, the output contacts are NOT voltage free (, then they are not dry contact), therefore, loads with different powers can not be connected to the module.

This hidden relay micromodule, Qubino Flush 2 Relays has an input to connect a temperature probe , which suits it to control heating or air conditioning systems.

What can be used for?

The Qubino Flush 2 Relays is ideal for remote control and change of electrical devices (eg lights or fans).

Energy control

Double relay Z-Wave Flush Qubino 2 Relays, makes measuring power consumption of the connected electrical appliances and of itself, when in "standby" only consume 0.4 W.

Very versatile

The Qubino Flush 2 Relays , can operate through an extensive range of temperatures from cold -10ÚC to suffocating 40ÚC (14Ú 104ÚF). It supports the connection of a digital temperature sensor, which is also useful for creating complex scenarios. Each module also acts as a repeater in order to improve the range and stability of the Z-Wave network.

Promotional video Qubino micromodulos

The simplest installation.

The extremely small size and a specially designed housing mean that the connection of the module inside a recessed mounting box is simple. The installation process, tested and approved by professional electricians , consists of only three simple steps:

1 - Remove the switches from the box and disconnect the cables.
2 - Connect the cables to the Qubino module and insert them into the box.
3 - Fix the switches to the box.

Video demonstration of the easy installation of Qubino Flush 2 Relays

The most proven and reliable Z-Wave modules

Qubino's Z-Wave modules are install-and-forget products. The Qubino products that we offer, are manufactured to last, so they only use electronic components that meet the most demanding quality levels. Our modules are also the most tested Z-Wave micromodules on the market. The Slovenian Institute of Quality and Measurement (SIQ), an independent European entity, checks the quality of the actual parameters of our products, including temperature increases, manufacturing, insulation resistance, electrical consumption and overloads according to the European standards of the highest quality according to the specification of the standard EN 60669-2-1.

Additional parameters for professionals.

The Qubino Flush 2 Relays micromodule   It has 15 additional parameters for its use by experts. Some of the most useful are

  • Adjustment of mono-stable (push-button) or bi-stable type
  • Activate or deactivate the ALL ON / ALL OFF functions
  • Automatic on / off output after set time

The micromodule can be controlled both through a Z-Wave network and through a wall switch. This module has been designed to be mounted inside a mechanism box and hidden behind a conventional wall switch.

We highlight as an advantage with respect to other regulators, that the Qubino Flush 2 Relays micromodule is able to control the electrical consumption of the connected load (lighting, fan ...). It also has a connector to which you can connect a temperature probe (optional, not included) to provide greater versatility to this module, which apart from the lighting control, offers control of electricity consumption and temperature information of the stay in the one that has been installed.

Electrical diagrams and technical specifications:

Electrical diagram 24VDC
N + VDC
L - C
Q1 Output of load electrical device no. one
Q2 Output of load electrical device no. 2
I2 Input for switch to control electrical device no.2
I1 Input for switch to control electrical device no.1
TS Terminal for digital temperature sensor (only for Flush 2 relays module compatible digital temperature sensor, which must be ordered separately).
Electrical Schemes Qubino Flush 1 Relay

Qubino Flush 2 relays
Electrical diagram 230VAC
N Neutral lead
L Live lead
Q1 Output for electical device no. one
Q2 Output for electrical device no. two
I2 Input for switch to control electrical device no.2
I1 Input for switch to control electrical device no.1
TS Terminal for digital temperature sensor (only for Flush 2 relays module compatible digital temperature sensor, which must be ordered separately).

Connection diagram of Qubino Flush 2 Relays retractable relays for a lighting circuit with "switched keys":

Commutated with Qubino's double Z-Wave relay

We emphasize that Qubino offers us strict quality, safety and durability standards in the manufacture of its hidden micromodules. It should be noted the selection of high quality components and high performance, such as the use of internal components of the Omron brand.

Feeding: 110 230 VAC ± 10%
50/60 Hz, (24 30 VDC)
Maximum AC output load (resistive load) * 2 X 4 A / 230 VAC
Maximum DC output load (resistive load) * 2 X 4 A / 30 VDC
Output circuit power of AC output (resistive load): 2 X 920 W (230 VAC)
Output circuit power of DC output (resistive load): 2 X 96 W (24 VDC)
Accuracy of power measurement: P = 0-200 W, +/- 2 W
P> 200 W, +/- 3%
Digital temperature sensor range: -50 ° ~ + 125 ° C, resolution 0.1 ° C
Cable length of the digital temperature sensor: 1000 mm
Operating Temperature: -10 ° ~ + 40 ° C
Distance up to 30 m indoors (depending on materials)
Dimensions (WxHxD) 41.8 x 36.8 x 15.4 mm
(packaging) (115 x 96 x 22)
Weight (including packaging) 48 g (64 g)
Electric consumption on standby 0.4 W
For installation in mechanism boxes Ø e 60 mm or 2 M
Switching by: Relay (2x)

* In the case of loads other than resistive loads, pay attention to the value of cosÆ and, if necessary, use a load lower than the nominal load. The maximum current for cosÆ = 0.4 is 2 A at 250 VAC, 3 A at 24 VDC.

Meets CE and ROHS Certifications

Download

Extended Z-Wave info

Name: Qubino Flush 2 relays
Manufacturer:QUBINO
Identifier:ZMNHB
Z-Wave Certification Number:ZC10-15100010
Hardware Plattform:ZM5202
FLiRS:NO
Role Type:Always On Slave
Short Description:Module is used for switching on or off two electrical devices and measure power consumtion.
Description:Flush 2 relays module is used for switching on or off two electrical devices (e.g. lights, fans, etc ...). The module can be controlled either through Z-Wave network or through the wall switches. The module is designed to be mounted inside a “flush mounting box”, hidden behind a traditional wall switch. Module measures power consumption of two electrical devices and supports connection of digital temperature sensor. It is designed to act as repeater in order to improve range and stability of Z-wave network.

Manual download HERE.

Group
Max Nodes
Description
1
1
Lifeline group (reserved for communication with the main controller), 1 node allowed.
2
16
basic on/off (triggered at change of the output Q1 state and reflecting its state) up to 16 nodes.
3
16
switch binary report (triggered at change of the output Q1 state and reflecting its state) up to 16 nodes.
4
16
power meter report (triggered at change of the output Q1 state) up to 16 nodes.
5
16
basic on/off (triggered at change of the output Q2 state and reflecting its state) up to 16 nodes.
6
16
switch binary report (triggered at change of the output Q2 state and reflecting its state) up to 16 nodes.
7
16
power meter report (triggered at change of the output Q2 state) up to 16 nodes.
8
16
multilevel sensor report (triggered at change of temperature sensor) up to 16 nodes.
Number
Size (Bytes)
Default Value
Name
Description
1
1
1
Input 1 switch type
Input 1 switch type
10
2
255
Activate / deactivate functions ALL ON/ALL OFF
Activate / deactivate functions ALL ON/ALL OFF Flush 2 relays module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system.
11
2
0
Automatic turning off output Q1 after set time
When relay Q1 is ON it goes automatically OFF after time defined by this parameter. Timer is reset to zero each time the module receive ON command regardless from where it comes (push button, associated module, controller,..).
110
2
32536
Temperature sensor offset settings
Set value is added or subtracted to actual measured value by sensor.
12
2
0
Automatic turning on output Q1 after set time
When relay Q1 is OFF it goes automatically ON after time defined by this parameter. Timer is reset to zero each time the module receive OFF command regardless from where it comes (push button, associated module, controller,..).
120
1
5
Digital temperature sensor reporting
If digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter.
13
2
0
Automatic turning off output Q2 after set time
When relay Q2 is ON it goes automatically OFF after time defined by this parameter. Timer is reset to zero each time the module receive ON command regardless from where it comes (push button, associated module, controller,..).
14
2
0
Automatic turning on output Q2 after set time
When relay Q2 is OFF it goes automatically ON after time defined by this parameter. Timer is reset to zero each time the module receive OFF command regardless from where it comes (push button, associated module, controller,..).
15
1
0
Automatic turning off / on seconds or milliseconds selection
Automatic turning off / on seconds or milliseconds selection Note that parameter is valid for both outputs Q1, Q2 and is the same for turning off or on.
2
1
1
Input 2 switch type
Input 2 switch type
30
1
0
Saving the state of the relays Q1 and Q2 after a power failure
Saving the state of the relays Q1 and Q2 after a power failure
40
1
10
Power reporting in Watts on power change for Q1
Set value means percentage, set value from 0 – 100 = 0% - 100%.
41
1
10
Power reporting in Watts on power change for Q2
Set value means percentage, set value from 0 – 100 = 0% - 100%
42
2
300
Power reporting in Watts by time interval for Q1
Set value means time interval (0 – 32535) in seconds, when power report is send.
43
2
300
Power reporting in Watts by time interval for Q2
Set value means time interval (0 – 32535) in seconds, when power report is send.
63
1
0
Output Q1 Switch selection
Set value means the type of the device that is connected to the Q1 output. The device type can be normally open (NO) or normally close (NC).
64
1
0
Output Q2 Switch selection
Set value means the type of the device that is connected to the Q2 output. The device type can be normally open (NO) or normally close (NC).
Inclusion
Module Inclusion (Adding to Z-Wave network)

• Connect module to power supply (with

temperature sensor connected - if purchased),

• enable add/remove mode on main controller

• auto-inclusion (works for about 5 seconds after connected to power supply) or

• press service button S for more than 2 second or

• press push button I1 three times within 3s (3 times change switch state within 3 seconds).

NOTE1: For auto-inclusion procedure, first set main controller into inclusion mode and then connect module to power supply.

NOTE2: When connecting temperature sensor to module that has already been included, you have to exclude module first. Switch off power supply , connect the sensor and re-include the module.

Exclusion
Module Exclusion/Reset (Removing from Z-Wave network)

• Connect module to power supply

• bring module within maximum 1 meter (3feet) of the main controller,

• enable add/remove mode on main controller,

• press service button S for more than 6 second or

• press push button I1 five times within 3s ( 5 times change switch state within 3 seconds) in the first 60 seconds after the module is connected to the power supply.

By this function all parameters of the module are set to default values and own ID is deleted.

If service button S is pressed more than 2 and less than 6second module is excluded, but configuration parameters are not set to default values

Factory Reset
Please use this procedure only in the event that your network primary controller is missing or otherwise inoperable.



If the service button S is pressed for mor ethan 6 seconds the module will be reset to the factory defoult state
Additional Special Features
- The module has the option to connect a digital temperature sensor

- small dimensions (WxHxD) 41,8x36,8x15,4mm

- power supply is 110 - 230 VAC ±10% 50/60Hz, 24-30VDC

- Electricity consumption 0,4W



 

Reviews

Grade 
12/1/2023

El mejor

Después de seis años de funcionamiento, los relés han dejado de conmutar y he tenido que sustituirlo. He comprado un Aeotec equivalente, más barato, y me he encontrado con que el Aeotec no puede programar un temporizador local (sí se puede con este) y con que la rapidez de respuesta al interruptor del Qubino es mucho mejor, ya que parece un interruptor físico. En el Aeotec se nota retraso.

Grade 
05/17/2021

Han ido a mejor

Siguen siendo los mas pequeños. los ultimos que me habeis enviado van mejor.

Grade 
11/8/2019

Muy pequeño

Me parecio muy pequeño cuando llegó. Funcioa bien. Envio rapido. Gracias.

  • 1 out of 1 people found this review useful.
Grade 
04/4/2019

Problema en Fibaro Solucionado!

Al instalar el producto con mi Fibaro Home Center Lite todo funcionaba correctamente pero observé que si encendía o apagaba desde los interruptores conectados al Qubino Flush 2 Relay, el controlador Fibaro no se enteraba. Domoticalia me ayudó con el problema y me indicó que debía cambiar la asociación del Fibaro de SingleChannel a Multichannel en el Gupo 1 del Endpoint 0. Ahora funciona perfectamente!

  • 1 out of 1 people found this review useful.

Write your review!

Write a review

Qubino Flush 2 Relays

Qubino Flush 2 Relays

Qubino Flush 2 relays Micromodule with 2 relays, used to turn on / off with this double switch, Z-Wave technology. Ideal to turn on or off two independent electrical loads. It also measures the energy consumption.

Accessories

Customers who bought this product also bought: