Qubino Flush Shutter Micromodule for home automation control of blinds, curtains, venetian blinds, awnings, etc. with the ability to reverse the polarity to handle 220v AC motors for this type of applications for opening and closing shutters and other "shutters" and solar protections for windows, facades and open spaces.

More details

Out of stock

60,11 €

-12%

68,30 €

Technical characteristics

Home Automation Technology Z-Wave Plus
Characteristic Consumption Measurement

More info

The smallest Z-Wave blind driver on the market

The Qubino Flush Shutter micromodule or "pickup" is the smallest Z-Wave module in the world capable of controlling shutter motors, roller or pulley systems, blinds, etc. You can control it remotely through the Z-Wave network or through wall switches / push buttons. It also measures the power consumption and supports the connection of a digital temperature sensor.

Qubino Flush Shutter

What is it for?

The Qubino Flush Shutter retractable micromodule is ideal for remotely controlling the motors of blinds, rollers, curtains, venetian blinds and sun screens, concealment for windows ... or similar.

This Qubino micro-module Z-Wave for the control of venetian blinds, blinds and blinds, allows to measure the electric consumption of the shutter motor connected in watts and the total consumption in kWh. The electrical consumption data can easily be picked up by your home automation controller.

In addition, now has a new functionality for tilting slats very useful in the application of this Qubino Flush Shutter micromodule for control of blinds application for the control of Venetian blinds.

Energy control

The control for blinds Z-Wave Qubino Flush Shutter , makes measurement of electrical consumption of the connected electrical device and of itself, when it is in "standby" only consumes 0.4 W.

Very versatile

The control for blinds, which some mistakenly call wifi blinds control, Qubino Flush Shutter , can operate through a wide range of temperatures from cold -10ÚC to suffocating 40ÚC (14Ú 104ÚF). It supports the connection of a digital temperature sensor, which is also useful for creating complex scenarios. Each module also acts as a repeater in order to improve the range and stability of the Z-Wave network.

The simplest installation

The extremely small size and a specially designed housing mean that the connection of the module inside a recessed mounting box is simple. The installation process, tested and approved by professional electricians , consists of only three simple steps:

1 - Remove the switches from the box and disconnect the cables.
2 - Connect the cables to the Qubino module and insert them into the box.
3 - Fix the switches to the box.

Installation Qubino Flush Shutter

The most proven and reliable Z-Wave modules

Qubino's Z-Wave modules are install-and-forget products. The Qubino products that we offer, are manufactured to last, so they only use electronic components that meet the most demanding levels of quality. Our modules are also the most tested Z-Wave micromodules on the market. The Slovenian Institute of Quality and Measurement (SIQ), an independent European entity, checks the quality of the actual parameters of our products, including temperature increases, manufacturing, insulation resistance, electrical consumption and overloads according to European standards of the highest quality according to the specification of standard EN 60669-2-1.

Video on "Venetian" control with the Qubino Flush Shutter module:

Additional parameters for professionals.

The Qubino Flush Shutter micromodule has 13 additional parameters for expert use. Some of the most useful are:

  • Reports of power in Watts in the energy consumption for Q1 or Q2
  • Define the selection between two available operating modes
  • Define the time required for the blinds to complete the complete cycle

The micromodule can be controlled either through a Z-Wave network or through a wall switch. This module has been designed to be mounted inside a mechanism box and hidden behind a conventional wall switch.

Technical specifications and electrical diagrams:

Roller Shutter Qubino Connection

Feeding: 110 230 VAC ± 10%
50/60 Hz, (24 30 VDC)

Rated load current of AC output (resistive load) *

2 X 4 A / 230 VAC
Maximum DC output load (resistive load) * n / a
Maximum output power AC (resistive load): 2 X 920 W (230 VAC)
Maximum output power DC resistive load): n / a
Accuracy of the power measurement: P = 0-200 W, +/- 2 W
P> 200 W, +/- 3%
Digital temperature sensor range: -50 ° ~ + 125 ° C, resolution 0.1 ° C
Cable length of the digital temperature sensor: 1000 mm
Operating Temperature: -10 ° ~ + 40 ° C
Distance up to 30 m indoors (depending on materials)
Dimensions (WxHxD) 41.8 x 36.8 x 15.4 mm
(packaging) (115 x 96 x 22)
Weight (including packaging) 48 g (64 g)
Electric consumption on standby 0.4 W
For installation in mechanism boxes Ø e 60 mm or 2 M
Switching by: Relays (x2)

Meets CE and ROHS Certifications

Download

Extended Z-Wave info

Name: Flush Shutter
Manufacturer:QUBINO
Identifier:ZMNHCD1
Z-Wave Certification Number:ZC10-17045565
Hardware Plattform:ZM5202
FLiRS:NO
Role Type:Always On Slave
Short Description:The Qubino Flush Shutter is the world's smallest Z-Wave module able to control the motors of blinds, rollers, shades, venetian blinds, etc.
Description:This Z-Wave module is used to control the motor of blinds, rollers, shades, venetian blinds, etc … The module can be controlled either through a Z-Wave network or through the wall switch. Precise positioning is supported for motors equipped with mechanical or electronic end switches. The module is designed to be mounted inside a “flush mounting box”, hidden behind a traditional wall switch. Module measures power consumption of motor and support connection of digital temperature sensor. It is designed to act as repeater in order to improve range and stability of Z-wave network.

Manual download HERE.

Group
Max Nodes
Description
1
0
Z-Wave Plus Lifeline
2
16
Basic on/off - triggered at change of the input I1 state and reflecting its state.
3
16
Basic on/off - triggered at change of the input I2 state and reflecting its state.
4
16
Basic on/off - triggered at sensing moving direction of roller: up=FF, down=0.
5
16
Basic on/off - triggered at reaching roller position: bottom=FF, top=0.
6
16
Basic on/off - triggered at reaching roller position: bottom=FF, not bottom=0.
7
16
Multilevel set - triggered at changes of value of the Flush Shutter DC position.
8
16
Multilevel set - triggered at changes of value of slats tilting position.
9
16
Multilevel sensor report - triggered at change of temperature sensor.
Number
Size (Bytes)
Default Value
Name
Description
10
2
255
Activate/deactivate functions ALL ON / ALL OFF
Flush Shutter responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controllers belonging to the system.
110
2
32536
Temperature sensor offset settings
Set value is added or subtracted to actual measured value by sensor.
120
1
5
Temperature sensor reporting
If digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter. Available configuration parameters (data type is 1 Byte DEC): • default value 5 = 0,5°C • 0 - Reporting disabled • 1-127 = 0,1°C - 12,7°C, step is 0,1°C
250
1
0
Unsecure / Secure Inclusion
Flush Shutter supports secure and unsecure inclusion. Even if the controller does not support security command classes, a dimmer could be included as unsecure and keep all the functionality.
40
1
10
Power reporting in Watts on power change for Q1 or Q2
Set value means percentage, set value from 0 – 100 = 0% - 100%.
42
2
0
Power reporting in Watts by time interval for Q1 or Q2
Set value means time interval (0 – 32767) in seconds, when power report is send.
71
1
0
Operating modes
This parameter defines selection between two available operating modes. NOTE1: After parameter change, first exclude module (without setting parameters to default value) then wait at least 30s and then re include the module!
72
2
150
Slats tilting full turn time
This parameter defines the time necessary for slats to make full turn (180 degrees).
73
1
1
Slats position
This parameter defines slats position after up/down movement through Z-wave or push-buttons. • default value 1 • 0 - Slats return to previously set position only in case of Z-wave control (not valid for limit switch positions). • 1 - Slats return to previously set position in case of Z-wave control, push-button operation or when the lower limit switch is reached.
74
2
0
Motor moving up/down time
This parameter defines Shutter motor moving time of complete opening or complete closing. NOTE: Important is that the reference position to manually set moving time is always Shutter lower position! Set parameter 74 to 0 and move the Shutter (using up/down push buttons or main controller UI) to the lowest desired position. On this Shutter position, set parameter 74 to time for complete opening or complete closing. At this point Shutter can be moved up (open) for set time, but can't be moved down because this position is already set as lower Shutter position. To change Shutter lower position below already set (manual recalibration), parameter 74 must be set to 0 and repeat the procedure described above. In case Shutter has limit switches, but anyhow you would like to limit opening/closing position by time, you can still do it. In case you put time that is longer that opening/closing real time limited by limit switches, Shutter will stop at limit switch, but the module relay will switch off after define time, not by Shutter limit switch. Take in consideration that in this condition, the positioning with slider through UI will not show correct Shutter position.
76
1
30
Motor operation detection
Power threshold to be interpreted when motor reach the limit switch.
78
1
0
Forced Shutter calibration
By modifying the parameters setting from 0 to 1 a Shutter enters the calibration mode.
85
1
30
– Power consumption max delay time
This parameter defines the max time before motor power consumption is read after one of the relays is switched ON. If there is no power consumption during this max time (motor not connected, damaged or requires higher time to start, motor in end position) the relay will switch OFF. Time is defined by entering it manually.
90
1
5
Time delay for next motor movement
This parameter defines the minimum time delay between next motor movement (minimum time between switching motor off and on again).
Basic
COMMAND_CLASS_BASIC
Switch Multilevel V3
COMMAND_CLASS_SWITCH_MULTILEVEL_V3
Association Group Information V2
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V2
Association V2
COMMAND_CLASS_ASSOCIATION_V2
Basic
COMMAND_CLASS_BASIC
Configuration
COMMAND_CLASS_CONFIGURATION
Device Reset Locally
COMMAND_CLASS_DEVICE_RESET_LOCALLY
Manufacturer Specific V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
Meter V4
COMMAND_CLASS_METER_V4
Multi-Channel Association V3
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3
Multi-Channel V4
COMMAND_CLASS_MULTI_CHANNEL_V4
Notification V5
COMMAND_CLASS_NOTIFICATION_V5
Powerlevel
COMMAND_CLASS_POWERLEVEL
Security S0
COMMAND_CLASS_SECURITY
Sensor Multilevel V7
COMMAND_CLASS_SENSOR_MULTILEVEL_V7
Switch All
COMMAND_CLASS_SWITCH_ALL
Switch Binary
COMMAND_CLASS_SWITCH_BINARY
Switch Multilevel V3
COMMAND_CLASS_SWITCH_MULTILEVEL_V3
Version V2
COMMAND_CLASS_VERSION_V2
Z-Wave Plus Info V2
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
Inclusion
• Connect module to power supply (with

temperature sensor connected - if purchased),

• auto-inclusion (works for about 5 seconds after connected to power supply) or

• press push button I1 three times within 3s (3 times change switch state within 3 seconds) or

• press service button S (only applicable for 24 V SELV supply voltage) for more than 2 second.



NOTE1: For auto-inclusion procedure, first set main controller into inclusion mode and then connect module to power supply.



NOTE2: When connecting temperature sensor to module that has already been included, you have to exclude module first. Switch off power supply, connect the sensor and re-include the module.

Exclusion
• Connect module to power supply

• bring module within maximum 1 meter (3 feet) of the main controller,

• enable add/remove mode on main controller,

• press push button I1 five times within 3s (5 times change switch state within 3 seconds) in the first 60 seconds after the module is connected to the power supply or

• press service button S (only applicable for 24 V SELV supply voltage) for more than 6 second.

By this function all parameters of the module are set to default values and own ID is deleted.



If push button I1 is pressed three times within 3s (or service button S is pressed more than 2 and less than 6 seconds) module is excluded, but configuration parameters are not set to default values.



NOTE: Please use this procedure only when the network primary controller is missing or otherwise inoperable.



NOTE: If the module is included with parameters 71 with value different to default and module reset is done, wait at least 30s before next inclusion

Factory Reset
• press push button I1 five times within 3s (5 times change switch state within 3 seconds) in the first 60 seconds after the module is connected to the power supply or

• press service button S (only applicable for 24 V SELV supply voltage) for more than 6 second.



NOTE: Please use this procedure only when the network primary controller is missing or otherwise inoperable.

Supported Notification Types
Select the Notification Types that the product handles (controllers), or sends (slaves).
Switch Type
Describes the type of operator for a switch.
Sensors
Sensor types supported by the product.
Supported Meter Type
Indicate which type of metering is supported by the device.
Color
If the product is only available in one color, pick the color from the list.

 

Reviews

Grade 
09/9/2019

Muy contento con la ayuda

Me han contado muy bien como funciona con mis motores. Gracias

Grade 
06/5/2018

Nada complicado

Soy usuario doméstico nivel bàsico. Después de todo el asesoramiento telefónico y lanzarme a comprarlo recibo el paquete. Parece complicado pero des del minuto uno que me han ayudado a conectarlo explicando el cuadro de cables y la posición. Una vez sabes uno, luego los demás ya son pan comido. Recomiendo la pieza por sus dimensiones pero sobretodo porqué te enseñan a ponerlo si tienes dudas.

Grade 
08/30/2016

Para las cortinas!

Tenia unas cortinas motorizadas con un sistema de radio. Cuando le puse este control de persianas Z-Wave, no me terminaban de cerrar. Me ayudaron en soporte a calibrarlo modificando un parámetro. Solucionado y muy contento. Son rápidos y muy silenciosos.

Write your review!

Write a review

Qubino Flush Shutter

Qubino Flush Shutter

Qubino Flush Shutter Micromodule for home automation control of blinds, curtains, venetian blinds, awnings, etc. with the ability to reverse the polarity to handle 220v AC motors for this type of applications for opening and closing shutters and other "shutters" and solar protections for windows, facades and open spaces.

Accessories

Customers who bought this product also bought: