Name: AC MASTER
Manufacturer:Remotec
Identifier:ZXT-600EU
Z-Wave Certification Number:ZC10-17085735
Hardware Plattform:ZM5202
FLiRS:YES
Role Type:Listening Sleeping Slave
Short Description:ZXT-600 AC Master -- Make your Infrared controlled air conditioner to be smart comfort control companion.
Description:ZXT-600 AC Master is a Z-Wave plus certified IR Bridge for split air conditioner control by receiving Z-Wave command and translating to Infrared command and flawlessly work with any Z-Wave compliant gateway.
With its over 250 brands built-in code library and ever-green up to date cloud IR database supporting advanced code learning search, ZXT-600 can easily set up and smart control most of AC brands and models actively worldwide by Z-Wave gateway.
The battery powered device will allow you to mount it anywhere you want such as wall, ceiling or put it on table and never compromise on the form factor. By supporting OTA function, gateway can enable ZXT-600 to update firmware if newest available.
Group
Max Nodes
Description
Number
Size (Bytes)
Default Value
Name
Description
25
1
0
Learn IR Code
Learn IR Code, refer to learning mapping table
26
1
0
Check IR Code Learning Status
Default: 0x00
range: 0 to 4 (0x00 to 0x04)
0(0x00) : Idle - IR Channel is idle
1(0x01) : OK - the last learning operation was completed successfully
2(0x02) : Learning - ZXT-600 is busy processing previous learning request
3(0x03) : Full – All locations are being used.
4(0x04) : The last learning request was failed
Note:The status value 0x01 and 0x04 will be reset to 0x00 after ZXT-600 receives a get command to this parameter.
27
2
857
Set IR Code Number from built-in code library
Refer to Code Finder Webpage
30
1
0
Set Auto Report condition Trigger by Room Temperature change
0(0x00) = Disable (Default)
(for saving battery life)
Auto report if room temperature is different from last report.
1(0x01) = 1°F (0.5°C)
2(0x02) = 2°F (1°C)
3(0x03) = 3°F (1.5°C)
4(0x04) = 4°F (2°C)
5(0x05) = 5°F (2.5°C)
6(0x06) = 6°F (3°C)
7(0x07) = 7°F (3.5°C)
8(0x08) = 8°F (4°C)
32
1
255
Set built-in IR Emitter Control
If there have two or more Air Conditioners with the same code set that are used in the same room, user can disable the built-in IR emitter and use the external IR emitter cable to control each air conditioner individually
0 or 255
(0x00 or 0xFF)
0(0x00): Disable
255(0xFF): Enable (Default)
33
1
1
Control AC "SWING" function
Default: 0x01
Range 0 to 1 (0x00 or 0x01)
0(0x00) : Swing OFF
1(0x01) : Swing Auto (Default)
34
1
8
Set Auto Report Condition by Time Interval
Auto report by the following time interval.
1(0x01) = 1 Hr
2(0x02) = 2 Hrs
3(0x03) = 3 Hrs
4(0x04) = 4 Hrs
5(0x05) = 5 Hrs
6(0x06) = 6 Hrs
7(0x07) = 7 Hrs
8(0x08) = 8 Hrs (Default)
37
1
0
Calibrate Temperature reading
Temperature offset value.
0(0x00) = 0°C (Default)
1(0x01) = 1°C
2(0x02) = 2°C
3(0x03) = 3°C
4(0x04) = 4°C
5(0x05) = 5°C
255(0xFF) = -1°C
254(0xFE) = -2°C
253(0xFD) = -3°C
252(0xFC) = -4°C
251(0xFB) = -5°C
Application Status
COMMAND_CLASS_APPLICATION_STATUS
Association Group Information V3
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3
Association V2
COMMAND_CLASS_ASSOCIATION_V2
Basic
COMMAND_CLASS_BASIC
Battery
COMMAND_CLASS_BATTERY
Configuration V2
COMMAND_CLASS_CONFIGURATION_V2
Device Reset Locally
COMMAND_CLASS_DEVICE_RESET_LOCALLY
Firmware Update Meta-Data V3
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V3
Manufacturer Specific V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
Powerlevel
COMMAND_CLASS_POWERLEVEL
Security S0
COMMAND_CLASS_SECURITY
Sensor Multilevel V7
COMMAND_CLASS_SENSOR_MULTILEVEL_V7
Thermostat Fan Mode V4
COMMAND_CLASS_THERMOSTAT_FAN_MODE_V4
Thermostat Mode V3
COMMAND_CLASS_THERMOSTAT_MODE_V3
Thermostat Setpoint V3
COMMAND_CLASS_THERMOSTAT_SETPOINT_V3
Version V2
COMMAND_CLASS_VERSION_V2
Z-Wave Plus Info V2
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
Inclusion
1, Refer to your primary controller to enter into the Inclusion Mode or Exclusion Mode
2, When it is prompted to enter it, please triple click the “PROG” button within 1 second.
3, Green Indicator flashes TWICE then stay off
Exclusion
1, Refer to your primary controller to enter into the Inclusion Mode or Exclusion Mode
2, When it is prompted to enter it, please triple click the “PROG” button within 1 second.
3, Green Indicator flashes TWICE then stay off
Factory Reset
Press and Hold “PROG” button for 3 seconds on AC Master, the Green Indicator will light up. DO NOT Release the “PROG” Button until Green Indicator flashes TWICE.
Remark : Please use this procedure only when the network primary controller is missing or otherwise inoperable.
Device Wake-Up
Press the ""PROG"" button to wakeup the unit
Sensors
Sensor types supported by the product.
Thermostat Modes
Select the mode(s) supported by the thermostat.
Color
If the product is only available in one color, pick the color from the list.
Battery Type
Enter the type (e.g. AA, CR2032, AAA) of the battery/batteries that the product uses.
Firmware Updatable
Indicates whether the firmware can be updated and whether it is done by the consumer or a technician.
Thermostat HVAC Systems Supported
Indicate which HVAC system or systems are supported by the thermostat.