Name: In Wall Smart Dimmer
Manufacturer:Philio
Identifier:PAD07
Z-Wave Certification Number:ZC10-17045563
Hardware Plattform:SD3502
FLiRS:NO
Role Type:Always On Slave
Short Description:PAD07 is a security enabled wireless dimmer, based on Z-Wave Plus technology. You can On/Off the light by pressing the button briefly, or a long pressing to control the brightness of dimmable light bulb.
Description:PAD07 is a security enabled wireless dimmer, based on Z-Wave Plus technology. Z-Wave PlusTM enabled devices displaying the Z-Wave PlusTM logo can also be used with it regardless of the manufacturer, and can also be used in other manufacturer’s Z-WaveTM enabled networks. You can On/Off the light by pressing the button briefly, or a long pressing to control the brightness of dimmable light bulb. This dimmer is a transceiver which is a security enabled device which based on Z-Wave Plus technology, and it is fully compatible with any Z-WaveTM enabled network. Since PAD07 supports Security Command Class, it can learn with a Secured enabled controller to fully utilize the device. Its functionality and supported command classes is identical when included as a secure and non-secure device.
Adding to Z-WaveTM Network
In the front casing, there is an on/off button (also an include button) with LED indicator below which is used to dim on and off or carries out inclusion, exclusion, reset or association. When first power applied, its LED flashes on and off alternately and repeatedly at 0.5 second intervals. It implies that it has not been assigned a node ID and start auto inclusion.
Auto Inclusion
The function of auto inclusion will be executed as long as the dimmer does not have Node ID and just connect the switch to main power. Note: Auto inclusion timeout is 2 minute during which the node information of explorer frame will be emitted once every several seconds. Unlike “inclusion” function as shown in the table below, the execution of auto inclusion is free from pressing the On/Off button on the dimmer.
Group
Max Nodes
Description
1
5
Lifeline
The Switch can be set to send reports to associated Z-Wave devices. It supports one association group with five nodes support for grouping 1. For group 1, the dimmer will report MULTILEVEL_SWITCH_REPORT, ALARM_REPORT and DEVICE_RESET_LOCALLY_NOTIFICATION.
2
5
Control_Key1
When the On/Off status changes or the dim level is achieved manually, it will send BASIC_SET command to group 2 nodes to make them unanimous.
Number
Size (Bytes)
Default Value
Name
Description
1
1
1
Dimmer Level Report mode
Whenever dimmer on/off state changes, it will send MULTILEVEL_SWITCH_REPORT to the nodes of group1. The default setting is Enable the function.
2
1
1
LED indication mode
1. Show dimmer State:When dimmer is on, LED is on. When dimmer is off, LED is off. The default setting is Show dimmer State.
2. Show Night mode:When dimmer is on, LED is off. When dimmer is off, LED is on.
3. One flash mode : When dimmer on/off state changes, LED will light on one second and then off.
3
1
1
External switch type
1. One switch mode:Only S1 can dim up the light bulb to brightest level, then dim down to darkest level, and so on…
2. Two switch mode:S1 and S2 can dim up the light bulb to brightest level, then dim down to darkest level, and so on…
3. Up/Down switch mode:S1 can only dim up the light bulb to brightest level, and S2 can only dim down to Off.
4
1
1
Restore dimmer state
Whenever the AC power return from lost, PAD02 will restore the switch state which could be Dimmer off、Last dimmer state、Dimmer on. The default setting is Last dimmer state.
Basic
COMMAND_CLASS_BASIC
Alarm
COMMAND_CLASS_ALARM
Association Group Info
COMMAND_CLASS_ASSOCIATION_GRP_INFO
Association V2
COMMAND_CLASS_ASSOCIATION_V2
Basic
COMMAND_CLASS_BASIC
Configuration
COMMAND_CLASS_CONFIGURATION
Device Reset Locally
COMMAND_CLASS_DEVICE_RESET_LOCALLY
Firmware Update Meta-Data V2
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
Manufacturer Specific V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
Powerlevel
COMMAND_CLASS_POWERLEVEL
Scene Activation
COMMAND_CLASS_SCENE_ACTIVATION
Scene Actuator Conf
COMMAND_CLASS_SCENE_ACTUATOR_CONF
Security S0
COMMAND_CLASS_SECURITY
Switch Multilevel V2
COMMAND_CLASS_SWITCH_MULTILEVEL_V2
Version V2
COMMAND_CLASS_VERSION_V2
Z-Wave Plus Info V2
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
Factory Reset
1. Pressing Include button of PAD07 three times within 2 seconds will enter inclusion mode.
2. Within 1 second, press Include button of PAD07 again for 5 seconds.
3. IDs are excluded.
*Please use this procedure only when the network primary controller is missing or otherwise inoperable.
Inclusion
1. Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer.
2. Pressing Include button of PAD07 three times within 2 seconds will enter inclusion mode.
Exclusion
1. Put your Z-Wave controller into exclusion mode by following the instructions provided by the controller manufacturer.
2. Pressing Include button of PAD07 three times within 2 seconds will enter exclusion mode.
3. Node ID has been excluded.
Switch Load Capacity Current
The amount of switch load energy the product is rated for in Amps
Firmware Updatable
Indicates whether the firmware can be updated and whether it is done by the consumer or a technician.
Neutral Wire Required
For electric in-wall/wired switches, indicate whether a neutral wire is required for installation.
Z-Wave Scene Type
Indicates which of the two types of Z-Wave scene command classes are supported. Scenes or Central Scene
Color
If the product is only available in one color, pick the color from the list.