Viewed products





Confianza Online


domoticalia.es/es/ Reviews with ekomi.es
Reduced price! Philio PAN04-1B Z-Wave Plus 2x1,5 Kw - Micromódulo interruptor de 2 relés y control de consumo View larger

Philio PAN04-1B Z-Wave Plus 2x1,5 Kw - Micro-module switch with 2 relays and consumption control

PHIEPAN04-1B

New

It is a Z-Wave Plus switch micromodule Double switch with Z-Wave energy measurement

More details

In Stock

41,65 €

-15%

49,00 €

Technical characteristics

Technology Z-Wave Plus
Characteristic Consumption Measurement

More info

The Philio PAN04-1B double micromodule switch allows you to control two lights or two remote devices with the Z-Wave + protocol while keeping your existing switches. Therefore, you will be able to operate the connected loads via existing switches, from a Z-Wave controller or directly from this button on the micromodule.
With its calibration technology, the PAN04-1B can be used to turn many types of lamps on and off, for example incandescent, fluorescent and LED.
On the other hand, this micro-module is capable of transmitting the instantaneous consumption of power (W) and cumulative (KWh) of the equipment that is loaded to it. It also has overload protection.
A Z-Wave home automation controller (remote control dongle ...) is necessary to integrate this module into your network if you already have an existing network.
The functions of the Z-Wave module include wireless repeater with other modules to ensure complete Z-Wave coverage of your home.


Please note that this module requires NEUTRAL to operate.


FEATURES:
Request two lights / fixtures remotely
Installs behind existing switches
Use rocker or pulse key
Adopts the latest Z-Wave + 500Series chip to support multi-channel operations and higher data rate
Optimized antenna range
Auto inclusion function
On off
Measure instantaneous and accumulated consumption
Overload protection
automatic status report after manual load control via switch
automatic consumption report at 5% change
Very low energy consumption, complies with European Directive 2009/125 / CE no. 1275/2008
Small, discreet and aesthetic
Ease of use and installation

TECHNICAL CHARACTERISTICS :
Module type: the Z-Wave + receiver
Power supply: 90 ~ 240VAC or 24-60V DC ± 10%
Power consumption: 0.48W
Wiring: 3 son, Neutral required
Maximum load: 1500W per output
Frequency: 868.42 MHz
Transmission distance: 30m
Dimensions: mm 47.5x39x15.6
Weight: 30g
Operating temperature: 0-40 ° C
Z-Wave certification: ZC08-13040018

Note: equivalent to Zipato PAN04-1B and to Airlive SA102

Extended Z-Wave info

Name: In Wall Dual relay(1 way) switch module
Manufacturer:Philio
Identifier:PAN04-1A
Z-Wave Certification Number:ZC10-14110001
Hardware Plattform:SD3502
FLiRS:NO
Role Type:Always On Slave
Short Description:This in-wall dual relay switch module is a transceiver which is a Z- Wave Plus™ enabled device and is fully compatible with any Z-Wave™ enabled network.
Description: This in-wall dual relay switch module is a transceiver which is a Z-Wave Plus™ enabled device and is fully compatible with any Z-Wave™ enabled network. Mini size design let the module can easily hide itself into the wall box and that will be good for the house decoration. There are many kind of application by using the module to switch AC power On and Off, one main application is the light control. The new smart relay calibration technology can reduce the inrush current caused by the load and let the module work perfectly with many kind of light like incandescent, fluorescent and LED light. This in-wall switch module is able to detect Instant power wattage and overload current (7.5A) of connected light or appliances. When detecting overload state, the Module will be disabled and its On/Off button will be lockout of which LED will flash quickly. However, disconnect and re-connect the Module will reset its overload condition to normal status.

Manual download HERE.

Group
Max Nodes
Description
1
1
For group 1, the Switch will report (1) ON/OFF status of Relay1 and Relay2 (2) Instant Power Consumption (Watt) of Relay1 and Relay2 (3) Accumulated Power Consumption (KWh) of Relay1 and Relay2 to Group1 node.
2
1
For group 2, the Switch will report (1) ON/OFF status of Relay1 (2) Instant Power Consumption (Watt) of Relay1 (3) Accumulated Power Consumption (KWh) of Relay1 to Group2 node.
3
1
For group 3, the Switch will report (1) ON/OFF status of Relay2 (2) Instant Power Consumption (Watt) of Relay2 (3) Accumulated Power Consumption (KWh) of Relay2 to Group3 node.
Number
Size (Bytes)
Default Value
Name
Description
1
2
720
Watt Meter Report Period
If the setting is configured for 1hour (set value =720), the PAN04 will report its instant power consumption every 1 hour to the node of correspond Group. The maximum interval to report its instant power consumption is 45 hours (5s*32767/3600=45hr).
10
1
1
Existence of Endpoint3
Multi-Channel Command is a good way to control relay1 and relay2 of PAN04 individually. The endpoint3 of PAN04 is related to both relay1 and relay2. In some condition it becomes redundant in Multi-Channel Command Class. When the Existence of Endpoint3 is set as 2, the endpoint3 will be disabled. The default value is 1. Endpoint1 and Endpoint2 are fixed, only Endpoint3 is dynamic.
2
2
6
KWH Meter Report Period
If the setting is configured for 1hour (set value =6), the PAN04 will report its Accumulated Power Consumption (KW/h) every 1 hour to the node of correspond Group. The maximum interval to report its Accumulated Power Consumption (KW/h) is 227.55 days (10min*32767/1440=227.55 days).
3
1
3
Selected Relay
If Controller not using Multi_Channel command class to access the relay of PAN04, you may configure the select value to react the Basic Command Class、Binary Switch Command Class or Meter Command Class V3.
4
1
1
Edge or Pulse mode or Edge-Toggl e mode
Edge mode: this mode is suitable for the bi stable wall switch that has indicator point on the switch, and the same position correspond to same state of relay1 and relay2. if the PAN04 relay change the state because of receiving Z-Wave RF command, it may need two times of change (switch on to off or switch off to on) to let relay back to the correspond state. Pulse mode: this mode is suitable for the toggle type wall switch to swap the state of Relay1 or Relay2. Edge-Toggle mode: this mode is suitable for the normal bi-stable switch, every time when change the state of the wall switch will also swap the state of Relay1 or Relay2.
5
2
750
Threshold of current for Load Caution
This is a warning when the current of load over the preset threshold value, if the setting value is 750, when the load current of Relay1 or Relay2 over this value, PAN04 will send current meter report to the node of correspond Group, the Range of the setting value is from 10 to 750, and the default value is 750.
6
2
10000
Threshold of KWh for Load Caution
This is a warning when the KWh of load over the preset threshold value, If the setting value is 10000, when the Accumulated Power Consumption of Relay1 or Relay2 over this value, PAN04 will send KWh Meter Report command to the node of correspond Group, minimum value is 1KWh and default value is 10000 kWh.
7
1
1
Restore switch state mode
Whenever the AC power return from lost, PAN04 will restore the switch state which could be SWITCH OFF、LAST SWITCH STATE、SWITCH ON. The default setting is LAST SWITCH STATE.
8
2
0
Auto off timer
Whenever PAN11 switches to on, the auto off timer begin to count down. After the timer decrease to zero, it will switch off automatically. However if Auto off timer is set as 0, the auto off function will be disabled. The default setting is 0.
9
1
0
RF off command mode
Whenever a switch off command, BASIC_SET 、 BINARY_SWITCH_SET 、 SWITCH_ALL_OFF, is received, it could be interpreted as 4 kinds of commands. 1. Switch Off : It switches to OFF state. The default setting is Switch Off. 2. Ignore : The switch off command will be ignored. 3. Switch Toggle : It switches to the inverse of current state. 4. Switch On : It switches to ON state.
Inclusion
1. Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer.
2. Pressing INCLUDE_BUTTON three times within 2 seconds will enter inclusion mode.
Exclusion
1. Put your Z-Wave controller into exclusion mode by following the instructions provided by the controller manufacturer.
2. Pressing INCLUDE_BUTTON three times within 2 seconds will enter exclusion mode.
Factory Reset
This procedure should only be used in the event the primary controller is lost or otherwise inoperable.

1. Pressing INCLUDE_BUTTON three times within 2 seconds will enter inclusion mode.
2. Within 1 second, press INCLUDE_BUTTON again for 5 seconds.
3. IDs are excluded.

 

Reviews

Write a review

Philio PAN04-1B Z-Wave Plus 2x1,5 Kw - Micro-module switch with 2 relays and consumption control

Philio PAN04-1B Z-Wave Plus 2x1,5 Kw - Micro-module switch with 2 relays and consumption control

It is a Z-Wave Plus switch micromodule Double switch with Z-Wave energy measurement

30 other products in the same category:

Customers who bought this product also bought: