Name: Single Function PIR Sensor
Manufacturer:Philio
Identifier:PSP05
Z-Wave Certification Number:ZC10-16105258
Hardware Plattform:SD3502
FLiRS:NO
Role Type:Reporting Sleeping Slave
Short Description:The PIR sensor PSP05 has PIR sensor function.
Description:The PIR sensor PSP05 has PIR sensor function,based on Z-Wave™ technology.
Group
Max Nodes
Description
Number
Size (Bytes)
Default Value
Name
Description
10
1
12
Auto Report Battery Time
The Interval time for auto report the battery level.
0 means turn off auto report battery.
The default value is 12.The tick time can setting by the configuration NO.20.
2
1
-1
Basic Set Level
Setting the BASIC command value to turn on the light.
-1(0xFF) means turn on the light.
For dimmer equipment 1 to 100 means the light strength.
0 means turn off the light.
Caution: The range is from 0x00 to 0xFF using hexadecimal notation.
20
1
30
Auto Report Tick Interval
The interval time for auto report each tick.
Setting this configuration will effect configuration NO.10.
The unit is 1 minute.
Caution 1:Setting to 0 means turn off all auto report function.
Caution 2:The range is from 0x00 to 0xFF using hexadecimal notation.
3
1
80
PIR Sensitivity
PIR sensitivity setting.
0 means disable the PIR motion.
1 means the lowest sensitivity.
99 means the highest sensitivity.
High sensitivity means can detected long distance,but if there is more noise signal in the environment, it will re-trigger too frequency.
6
1
5
Multi-Sensor Function Switch
Multisensor function switch.Using bit to control.
8
1
3
PIR Re-Detect Interval Time
In the normal mode, after the PIR motion detected, setting the re-detect time.
8 seconds per tick,default tick is 3(24 seconds).
Setting the suitable value to prevent received the trigger signal too frequently. Also can save the battery energy.
9
1
4
Turn Off Light Time
After turn on the light,setting the delay time to turn off the lighting when the PIR motion to turn off the lighting when the PIR motion is not detected.8 seconds per tick,default tick is 4(32 seconds).
0 means never send turn off light command.
Basic
COMMAND_CLASS_BASIC
Association Group Info
COMMAND_CLASS_ASSOCIATION_GRP_INFO
Association V2
COMMAND_CLASS_ASSOCIATION_V2
Battery
COMMAND_CLASS_BATTERY
Configuration
COMMAND_CLASS_CONFIGURATION
Device Reset Locally
COMMAND_CLASS_DEVICE_RESET_LOCALLY
Manufacturer Specific V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
Multi-Command
COMMAND_CLASS_MULTI_CMD
Notification V4
COMMAND_CLASS_NOTIFICATION_V4
Powerlevel
COMMAND_CLASS_POWERLEVEL
Security S0
COMMAND_CLASS_SECURITY
Sensor Binary V2
COMMAND_CLASS_SENSOR_BINARY_V2
Version V2
COMMAND_CLASS_VERSION_V2
Wake Up V2
COMMAND_CLASS_WAKE_UP_V2
Z-Wave Plus Info V2
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
Factory Reset
There is a button on PSP05.
1. Pressing button for about 5 seconds.
2. IDs are excluded and all settings will reset to factory default.
Notice: Use this procedure only in the event that the primary controller is lost or otherwise inoperable.
Device Wake-Up
There is a button on PSP05.
Press the button once, the device will awake 10 seconds.
Inclusion
There is a button on PSP05.
1. Have Z-Wave™ Controller entered inclusion mode.
2. Pressing button once to enter the inclusion mode.
3. After add successful, the device will wake to receive the setting command from Z-Wave™ Controller about 20 seconds.
Exclusion
There is a button on PSP05.
1. Have Z-Wave™ Controller entered exclusion mode.
2. Pressing button once to enter the exclusion mode.
Color
If the product is only available in one color, pick the color from the list.
Battery Quantity
Enter the number of batteries of the designated type that the product uses.
Battery Type
Enter the type (e.g. AA, CR2032, AAA) of the battery/batteries that the product uses.
Sensors
Sensor types supported by the product.