Name: Siren with LED strobe light
Manufacturer:Vision
Identifier:ZM1601EU-5
Z-Wave Certification Number:ZC10-14040001
Hardware Plattform:ZM5202
FLiRS:YES
Role Type:Listening Sleeping Slave
Short Description:Siren with LED strobe light, Battery Operated (4*AA)
Description:This product will sound a loud siren and flash a strobe light when an alarm message or alert is received on any Z-Wave™ enabled network. This siren is a Z-Wave™ enabled device (interoperable, two-way RF mesh networking technology) and is fully compatible with any Z-Wave™ enabled network. Configuration modes are provided to select; Strobe, Siren or Both and to set Alarm Auto Stop time. Features also include Self-Protection (tamper proof) alert and Battery Life Alert. 105dB siren at 1 meter.
Group
Max Nodes
Description
1
5
LifeLine association for central static controller
COMMAND_CLASS_DEVICE_RESET_LOCALLY,
DEVICE_RESET_LOCALLY_NOTIFICATION,
COMMAND_CLASS_BATTERY,
BATTERY_REPORT,
COMMAND_CLASS_NOTIFICATION_V4,
NOTIFICATION_REPORT_V4
Number
Size (Bytes)
Default Value
Name
Description
2
1
0
Alarm Auto Stop Time
Additional Special Features
Battery Life Reporting, Select strobe only, siren only or both; Sleect Alarm Reset Time, Tamper Switch, Over the air updates (OTA function), Self Protection Mode, PowerLevel Control, Detecting Battery Voltage (report back when low voltage) , 105dB at 1 meter
Factory Reset
All user and network settings will be cleared and the device reset to factory defaults when the device is excluded.
Inclusion
For “Inclusion” (adding to) a network, put the Z-Wave™ network controller into “inclusion” mode, and following its instruction to add the ZM 1601 to your controller. To get the ZM 1601 in the “inclusion” mode, open the bracket and press the program switch of ZM 1601 for 1 second at least & release to be included. After waiting a few seconds the LED Setting Lighting should go off, if not, please try again. (After sending the Z-Wave NIF one time if the ZM1601 is not included it will send 4 times Network Wide Inclusion request every 4 ~ 6 seconds for auto inclusion. The orange LED will flash again if the siren has not been included or the orange LED will go off after inclusion.)
Exclusion
For “Exclusion” from (removing from) a network: Set up the Z-Wave™ network controller into “exclusion” mode, and following its instruction to delete the ZM 1601 from your controller. Press the program switch of ZM 1601 for 1 second at least & release to be excluded. Note: a. LED setting light will flash (orange color) continuously in Exclusion condition for 25 seconds. b. All user and network settings will be cleared and the device reset to factory defaults when the device is excluded.
Device Wake-Up