Viewed products





Confianza Online


domoticalia.es/es/ Reviews with ekomi.es

POPP Mold Detector Z-Wave Plus

POPE701202

New

To protect your home against mold the detector measures temperature and humidity of its environment. The Mold Detector notices specified combinations of temperature and humidity, which can lead to the formation of mold. 

More details

In Stock

34,99 €

Technical characteristics

Technology Z-Wave Plus

More info

The POPP Mold Detector protects your home against mold formation. The detector has a unique and elegant design which fits in every Smart Home. Because of his slim design the Mold Detector can be placed at any position, which needs to be supervised.

To protect your home against mold the detector measures temperature and humidity of its environment. The Mold Detector notices specified combinations of temperature and humidity, which can lead to the formation of mold. If a specific range of humidity and temperature, which leads to mold formation, is reached the detector sends out a warning to your Z-Wave Smart Home gateway. With that you will always be informed about the danger of mold formation.

Thanks to the Mold Detector the damage on buildings and apartment through mold can be avoided. If the Mold Detector dectects any danger of mold, the air system can be started automatically, the autamtic window motor can be opened or the residents will be alluded via push message to air the rooms.

Specifications:

  • Temperature measurement in °C +/- 0.2°C, 0 to +65°C
  • Humidity measurement in % 0-100%; +/- 3.5%; +/- Hysteresis
  • Warning if there is a mold formation danger based in temperature and humidity values
  • LED to signal when mold formation danger occurs
  • Up to 3 years battery lifetime
  • Z-Wave Plus
  • Z-Wave Smart Start and S2 Security
  • Dimensions in mm: 18x20x70

Scope of delivery:

  • POPP Mold Detector
  • 1x ½ AA 3.6V Lithium battery
  • Adhesive and screws
  • Quickstart guide in EN & DE
Article Dimensions (WxHxL) 18 x 20 x 70 mm
Package Dimensions (WxHxL) 102 x 102 x 55 mm
Article net weight 0.012 Kg
Article gross weight 0.073 Kg
Z-Wave Plus
Z-Wave S2
WEEE
CE
IP-Rating IP20

Extended Z-Wave info

Name: Mold Detector
Manufacturer:Popp & Co.
Identifier:POPE700878
Z-Wave Certification Number:ZC10-19026384
Hardware Plattform:ZM5101
FLiRS:NO
Role Type:Reporting Sleeping Slave
Short Description:The device measures environmental parameters and will warn when the air in the room will allow growth of mold.
Description:This device measures the three air quality parameters temperature, humidity and dew point an reports them to a central controller. Beside this, the device can directly control groups of other Z-Wave devices on over- and undershooting a set temperature and/or humidity parameter. This can be used to establish control loops for temperature and humidity. The device wakes up every 4 minutes to measure the values and it will send unsolicited reports when values change. Additionally, the device will report all values on request. The mold detector is actively monitoring the danger of mold in a room based on the temperature and humidity and will issue alarm warnings when critical air conditions met. Wireless Alarm and red and a green blinking LED will indicate a mold condition. This local LED warning function is also available when the device is not included in any Z-Wave network and works stand alone.

Manual download HERE.

Group
Max Nodes
Description
1
5
Z-Wave Plus Lifeline
2
5
Temperature High Trigger
3
5
Temperature Low Trigger
4
5
Humidity High Trigger
5
5
Humidity Low Trigger
Number
Size (Bytes)
Default Value
Name
Description
1
1
20
Minimum Temperature change to report
This value defines the minimum change of temperature to cause an unsolicited report of humidity to the central controller using Lifeline. If the value is set to 0, there will be no reports sent to the controller, when the temperature changes. However, periodic reports, managed by configuration parameter 4, may still be active.
10
1
0
High Temperature Trigger BASIC Set Command Value
This defines what BASIC command shall be sent out into association group 2
11
1
-1
Low Humidity Trigger BASIC Set Command Value
This defines what BASIC command shall be sent out into association group 5
12
1
0
High Humidity Trigger BASIC Set Command Value
This defines what BASIC command shall be sent out into association group 4
2
1
7
Minimum humidity change to report
This value defines the minimum change of humidity to cause an unsolicited report of humidity to the central controller using Lifeline. If the value is set to 0, there will be no reports sent to the controller, when the humidity changes. However, periodic reports, managed by configuration parameter 4, may still be active.
4
2
43200
Periodic Reports
This parameter defines the time interval to send an unsolicited report. If the value is set to 0, there will be no periodic reports sent to the controller. However, reports on temperature/humidity changes, managed by configuration parameters 1 and 2, may still be active.
5
2
0
Temperature Upper Watermark value
This parameter defines a temperature. If the measured temperature surpasses this watermark a BASIC command is sent into Association Group 2.
6
2
0
Temperature Lower Watermark value
This parameter defines a temperature. If the measured temperature drops below this watermark a BASIC command is sent into Association Group 3
7
1
0
Humidity Upper Watermark value
This parameter defines a relative humidity. If the measured relative humidity surpasses this watermark a BASIC command is sent into Association Group 4
8
1
0
Humidity Lower Watermark value
This parameter defines a relative humidity. If the measured temperature drops below this relative humidity a BASIC command is sent into Association Group 5
9
1
-1
Low Temperature Trigger BASIC Set Command Value
This defines what BASIC command shall be sent out into association group 3
Basic
COMMAND_CLASS_BASIC
Association Group Info
COMMAND_CLASS_ASSOCIATION_GRP_INFO
Association V2
COMMAND_CLASS_ASSOCIATION_V2
Battery
COMMAND_CLASS_BATTERY
Configuration
COMMAND_CLASS_CONFIGURATION
Device Reset Locally
COMMAND_CLASS_DEVICE_RESET_LOCALLY
Firmware Update Meta-Data V4
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
Manufacturer Specific V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
Multi-Channel Association V3
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3
Notification V8
COMMAND_CLASS_NOTIFICATION_V8
Powerlevel
COMMAND_CLASS_POWERLEVEL
Security S2
COMMAND_CLASS_SECURITY_2
Sensor Binary V2
COMMAND_CLASS_SENSOR_BINARY_V2
Sensor Multilevel V8
COMMAND_CLASS_SENSOR_MULTILEVEL_V8
Supervision
COMMAND_CLASS_SUPERVISION
Transport Service V2
COMMAND_CLASS_TRANSPORT_SERVICE_V2
Version V3
COMMAND_CLASS_VERSION_V3
Wake Up V2
COMMAND_CLASS_WAKE_UP_V2
Z-Wave Plus Info V2
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
Factory Reset
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
Inclusion
Tripple clicking the tamper button includes (adds) the device.
Exclusion
Tripple clicking the tamper button excludes (removes) the device.
Learn Mode (adding another controller)
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.



Once Cover is removed and tamper switch is tripped, push the tamper for 5 seconds until red LED blinks. Then release tamper and push it again for 5 seconds until LED blinks.
Device Wake-Up
A single click on the tamper button will wakeup the device.
S2 Unauthenticated
S2_UNAUTHENTICATED
Battery Quantity
Enter the number of batteries of the designated type that the product uses.
Battery Type
Enter the type (e.g. AA, CR2032, AAA) of the battery/batteries that the product uses.
Color
If the product is only available in one color, pick the color from the list.
Firmware Updatable
Indicates whether the firmware can be updated and whether it is done by the consumer or a technician.
Sensors
Sensor types supported by the product.
Supported Notification Types
Select the Notification Types that the product handles (controllers), or sends (slaves).

 

Reviews

Write a review

POPP Mold Detector Z-Wave Plus

POPP Mold Detector Z-Wave Plus

To protect your home against mold the detector measures temperature and humidity of its environment. The Mold Detector notices specified combinations of temperature and humidity, which can lead to the formation of mold. 

23 other products in the same category:

Customers who bought this product also bought: