Viewed products





Confianza Online


domoticalia.es/es/ Reviews with ekomi.es

HELTUN Z-Wave thermostat for fan coil units (White)

HE-FT01-SW

New

The Heltun thermostat for Fan Coil or fan coil units is a programmable Z-Wave electronic room thermostat for heat / cold. It is designed for recessed mounting in most standard wall boxes. White color

More details

Out of stock

156,39 €

-8%

169,99 €

Technical characteristics

Technology Z-Wave 700 Series

More info

This is your comfort: take control

Considering thermal comfort, which aspects are the most important? Is it the general temperature of the room? Temperature of heating or cooling? Speed of conditioning and ventilation? Or maybe something else? Whatever the need, HELTUN guarantees that you take care of yourself.

Elegance

Powerful, efficient and well designed, HELTUN is the thinnest and most elegant thermostat on the market. With a crystalline glass panel, its recycled plastic housing resistant to fire and short circuited is only 9 mm thick.

Design

HELTUN adapts perfectly to your interior design and is available in 24 combinations: 4 frame colors (silver, chrome, white and black) and 6 types of glass (white, black, yellow, green, red, blue). You can choose any style that suits your taste.

Internal sensors

In addition to the temperature control sensors, the HELTUN thermostat also incorporates humidity and light sensors.

Heltun Fan Coil Thermostat

Additional sensors that help you save energy

When an electronic device performs its function, a certain amount of heat is generated. As a result, the ambient temperature is generally incorrectly reported with an accuracy of 1.5 to 2.0 degrees Celsius. HELTUN engineers have added two additional internal sensors that take into account the excess heat generated by the device itself, while a special compensation software calculates the ambient temperature with an incredible accuracy of 0.2 to 0.3 degrees Celsius.

Heltun Fan Coil ZWave Thermostat

Tickets and departures

The main power input is 100-250VAC. It has 5 relay outputs each with a maximum load of 5A.

The thermostat also has two independent inputs for the relay channels, which allows you to control systems with different energy sources or use outputs as dry contacts. For example, to turn on / off the 220 VAC light and control the motorized valve with a 24 VDC power supply.

Input 1 with the required power supply is for relay channels 1, 2 and 3, which can withstand loads up to 15A max.

Input 2 with the required power supply is for relay channels 4 and 5, which can withstand loads up to 10A max.

Heltun Fan Coil Zwave thermostat connection

Know your energy consumption

Thanks to HELTUN's integrated power consumption logic, you can precisely control the amount of energy used each day, each week or each month for each channel.

Simply specify the wattage consumption for each retransmission channel and the special logic will calculate the total consumption based on the time elapsed when the output is in the ON state.

Controls

The touch buttons of the HELTUN thermostat are so sensitive that they react even before touching them physically, treating the action at a distance of 1 to 2 mm. The buttons are:

"SPEED" button to control the fan speed (cooling, heating or ventilation).
The "Mode" button quickly changes the operating mode of the thermostat (for example, switching to economy mode or comfort mode, etc.). Press and hold the Mode button to open the setup menu for up to 20 different configurations and thermostat settings.
"Time" button that allows you to quickly adjust the temperature for different times of the day.
"Climate" button: to select air conditioning mode: heating only, cooling only, heating and cooling, ventilation only
Keys "+" and "-" to adjust the temperature

LCD screen

The large LCD screen of the HELTUN thermostat displays all the necessary information simultaneously and, unlike many other models, does not require any additional commands to access it. There is instant access to the information of all sensors: room temperature, air humidity, current temperature setting, thermostat operating mode, climate mode, fan speed, date and time.

The automatic control of the brightness of the screen adapts perfectly to the conditions of ambient light, which facilitates the reading even in the dark.

Modes of Operation

The COM and ECO modes constantly maintain the set temperature. The user can easily change the set temperature for each mode. To do this, simply press the "mode" button to select the desired mode and use the "+" and "-" buttons to set the desired temperature.

The HOUR mode allows you to set a different temperature for the morning, day, afternoon and night periods for each day of the week.

Weather modes

In the heating and cooling mode, the thermostat will constantly maintain the desired temperature. If the ambient temperature of the room is higher than the set temperature, the unit switches to the cooling state. If the temperature of the room drops, the thermostat switches to the heating state.

Only in heating mode, the thermostat will switch to the heating state if the ambient temperature of the room is below the set temperature and it will go to the inactive state if the ambient temperature is higher than required.

Only in cooling mode, the thermostat will switch to the cooling state if the ambient temperature is higher than the set temperature and will enter the idle state if the ambient temperature is lower than required.

In Ventilation mode, the thermostat will only be ventilated.

Heltun Fan Coil Zwave thermostat connection

TIME mode

Reduce energy consumption by up to 50% and help protect the environment by activating the HOUR mode. Adjust the temperature according to your habits, reducing it during your absence and increase at night and early in the morning.

On average, people spend around 12-14 hours a day at home. The rest of the time, the house is empty and requires only a minimum of heating. Consider 7/8 hours of sleep in the hours you spend at home, taking into account that the optimal temperature for sleeping is considered to be 18 degrees Celsius.

The thermostat can be adjusted individually for the time and temperature for morning, day, evening and night. For example, it can be assigned to Monday morning from 7:00, then to the temperature of the day starting at 9:00 (absent for work reasons, etc.), and then in the afternoon from the 18:00 (half an hour before the return). occupants). The nocturnal diet begins at 23:00 (bedtime).

You can have separate temperature settings for the 4 periods. But that's not all: the temperature can be programmed for each day of the week and weekends can be managed differently.

Heltun Fan Coil Zwave thermostat connection

Fan speed

The fan speed (heating, cooling or fan power) can be controlled manually or in automatic mode. There are 4 speed levels: off, low, medium, high.

In automatic mode, the thermostat logic will automatically select the speed level according to the desired temperature difference and the ambient temperature.

If the difference is less than 1.0 ° C, the thermostat will select the slow speed level.

If the difference is between 1.0 C and 2.0 C, the thermostat will select the average speed level.

If the difference is greater than 2.0 ° C, the thermostat will select the high speed level.

When the ambient temperature reaches the required temperature, the thermostat switches to the idle state (fan deactivated).

Heltun Fan Coil Zwave fan thermostat

Hysteresis

The hysteresis defines when the system should turn on / off the heating / cooling when the temperature changes. For example, if the desired temperature is 25 ° C and the hysteresis value is set to 0.5 degrees, heating is enabled when the ambient temperature drops to 24.5 ° C.

The higher the hysteresis value, the more energy will be saved, but at the same time the room temperature variations will be higher. The default value is 0.5 degrees.

Safe and protected

If the main power supply is cut off or disconnected, the internal memory is not erased. Once you have reactivated the device, all saved settings will be fully functional.

To prevent children from interfering with the setting of your thermostat, you can enable the child protection mode.

Z-Wave Plus S2 certificate

Connect your HELTUN devices to the home control system using the latest Z-Wave Plus secure chip with the new security framework 2 (S2) (AES 256 encryption method for data transfer).

The HELTUN thermostat is compatible with all Z-WAVE certified peripherals and controllers.

With the Z-Wave controller, you can manage all the functions of the thermostat through a mobile application, including the change of temperature and mode, see precise graphics of power consumption and more.

In addition, up to 10 separate devices can be connected to the thermostat. You can associate the Heltun thermostat with any on-off switch compatible with Z-Wave or other thermostat and control different climate systems in the room, or even connect motion sensors and adjust the mode change through the identification of the person and the general movement. inside the house

FUNCTIONS:

Z-Wave thermostat for Fan Coil
Inclusion / exclusion in a Z-Wave network
Control by association of 10 network devices.
6 operating modes:
COM - Comfort Mode
ECO - Energy saving mode.
TIME - TIME mode
Temperature schedule of 4 periods during the 7 days of the week.
Choice of heating mode:
Heating and air conditioning.
Only heating
Only cooling
ventilation
Energy consumption meter for each channel.
Reset the consumption counter.
Calibration of temperature sensors.
Temperature ranges: 4 ° C to 37 ° C
Temperature limiter
Choose a temperature hysteresis
Choice of unit (Celsius / Fahrenheit)
Adjustable LCD screen brightness: Auto or Manual
LCD screen in standby mode
Lock for children
Return to factory settings
TECHNICAL CHARACTERISTICS :

Dimensions of the front frame: 89x89x9mm.
Rear dimensions: 53x53x28mm.
Material: flame retardant plastic, tempered glass
Frame colors: white
Colors of glass: white.
LCD: 73x42mm, black with white icons.
6 sensitive capacitive touch buttons
Operating temperature: -10 ° C to + 60 ° C
Power supply: 100V - 230VAC, 50Hz / 60Hz
Power consumption: 2 W
Maximum resistive load: 5A for each channel.
Relay lifespan: 100,000 switching
Internal ambient light sensor
Internal temperature sensor
Measuring range: -40 ° C to + 125 ° C
Accuracy: ± 0.5 ° C
Internal humidity sensor
Measuring range: 0 to 80% RH
Accuracy: ± 3.0% RH
IP class: IP21
Z-Wave frequency: EU-868/869 MHz
SDK Z-Wave: V6.71
Z-Wave Plus Module: ZM5202

Extended Z-Wave info

Name: Fan Coil Thermostat
Manufacturer:HELTUN
Identifier:HE-FT01
Z-Wave Certification Number:ZC12-20010025
Hardware Plattform:ZGM130
FLiRS:NO
Role Type:Always On Slave
Short Description:Advanced Programmable Z-Wave Plus v2 Thermostat for Fan Coil Heating/Cooling Systems—with S2 security and Smart Start on the Z-Wave 700 platform.
Description:The HE-FT01 is HELTUN’s advanced programmable Z-Wave thermostat for heating/cooling systems such as fan coil units, floor convectors, and wall, window, or ceiling mounted air conditioning units. The HE-FT01 thermostat is ‘impossibly thin’ on the wall while still being packed full of features, delivering highly accurate comfort control through proprietary technology and four built-in sensors. You can monitor and control the HE-FT01 from anywhere in the world using a Z-Wave hub and your smartphone.* And because it uses Z-Wave Plus version 2, Smart Start, S2 Security and 700 platform technologies, the HE-FT01 can be placed up to 100 meters away from the hub and is a snap to install. Best of all, the built-in Power Consumption System precisely monitors how much energy you used during any particular day, week or month, helping you save money on energy costs while staying comfortable all year long. The HELTUN HE-FT01 is part of an entire line of smart, connected products designed to provide the best technology has to offer without compromising stylish living. (*hub and smartphone not included)

Manual download HERE.

Group
Max Nodes
Description
1
1
This is the Lifeline Group 1 which sends status (lifeline) reports to the primary controller.
2
1
“Fan Low Speed (OUT-1)” is used to turn the associated devices on/off reflecting OUT-1 operation.
3
1
“Fan Medium Speed (OUT-2)” is used to turn the associated devices on/off reflecting OUT-2 operation.
4
1
“Fan High Speed (OUT-3)” is used to turn the associated devices on/off reflecting OUT-3 operation.
5
1
“Heater (OUT-4)” is used to turn the associated devices on/off reflecting OUT-4 operation.
6
1
“Cooler (OUT-5)” is used to turn the associated devices on/off reflecting OUT-5 operation.
Number
Size (Bytes)
Default Value
Name
Description
1
1
1
TIME CORRECTION
Time correction by controller
10
1
10
MANUAL BRIGHTNESS
Display manual brightness level. The Display Brightness Level Parameter will take effect when Parameter 22 is set to Manual Control (value = 0). Note: The environment illumination is displayed in the TIME position and also can be checked at any time via a Z-Wave gateway.
11
1
15
TOUCH THRESHOLD
Touch buttons sensitivity. 5 = Highly sensitive. 50 = Lowest sensitivity. Note: Setting the sensitivity too high can lead to false touch detection. We recommend not changing this Parameter unless there is a need to do so.
12
1
0
RESERVED
Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.
13
1
0
RESERVED
Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.
14
1
2
BASIC SET MODE
Mode to switch to on Basic Set Action command This Parameter defines which Operating Mode the HE-FT01 reverts to if the Basic Set command is received. If the Basic Set command value is 0 (OFF state) the HE-FT01 will go to OFF mode and switch the operating state to IDLE. If the Basic Set command value is 0xFF (ON state) the HE-FT01 will change the Mode to the corresponding Parameter value.
15
1
0
RESERVED
Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.
16
1
0
RESERVED
Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.
17
1
0
RESERVED
Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.
18
1
0
RESERVED
Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.
19
1
0
RESERVED
Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.
2
1
1
TIME FORMAT
Time format
20
1
0
RESERVED
Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.
21
1
0
RESERVED
Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.
22
1
0
RESERVED
Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.
23
1
0
RESERVED
Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.
24
1
0
RESERVED
Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.
25
1
0
RESERVED
Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.
26
1
0
RESERVED
Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.
27
1
0
RESERVED
Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.
28
1
0
RESERVED
Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.
29
1
0
RESERVED
Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.
3
1
1
WEEKDAY
Week day. This parameter allows manually adjustment of the day of the week in case if the thermostat is not connected to any Z-Wave gateway or Parameter 09 (auto-correction) is selected as 0.
30
1
0
RESERVED
Parameter reserved by the manufacturer. Setting this parameter will have no impact on DUT functionality.
31
1
10
SENSORS REPORT TIME
Sensors consecutive reporting interval, minutes. When the device is connected to the Z-Wave gateway (controller), it periodically sends to the gateway reports from its room & floor temperature, humidity and light sensors even if there are not changes in the values. This Parameter defines the interval between consecutive reports. The value can be adjusted from 1 min to 120 min. Note: If the sensor readings change, the device will send the report to the gateway regardless of this parameter value. In order not to increase traffic on your network, it is not recommended to reduce the value of this parameter. We recommend to reduce the value of this parameter only in case of poor connection, when reports from the device does not always reach the gateway.
32
1
10
CONSUMPTION REPORT TIME
This Parameter defines the interval (in minutes) between consecutive reports of real time and cumulative energy consumption data to the gateway. The value can be adjusted from 1 min to 120 min. The factory default value is 10 min. Note: If the sensor readings change, the device will send the report to the gateway regardless of this parameter value. In order to not increase traffic on your network, we recommend not reducing this value.
33
1
5
TEMPERATURE THRESHOLD
Temperature difference to send to controller, value x10. This parameter determines the change in temperature level (in °C) resulting in temperature sensors report being sent to the gateway. The value of this parameter should be x10, e.g. for 0.4°C use value 40. From 0.5°C to 10°C can be selected. The factory default value is 0.5°C (5).
34
1
2
HUMIDITY THRESHOLD
This parameter determines the percentage change in relative humidity level which will trigger a report being sent to the gateway. From 2% to 25% can be selected.
35
1
50
LIGHT THRESHOLD
This parameter determines the change in the ambient illumination level that will trigger a report being sent to the gateway.
36
2
0
OUT–1 LOAD
Power of the Relay 1 load in W. It is possible to specify the consumption of the loads in watts for each relays channel. The device will calculate total consumption relative to the time, during which the output of the relays is in the ON state.
37
2
0
OUT-2 LOAD
Power of the Relay 2 load in W. It is possible to specify the consumption of the loads in watts for each relays channel. The device will calculate total consumption relative to the time, during which the output of the relays is in the ON state.
38
2
0
OUT–3 LOAD
Power of the Relay 3 load in W. It is possible to specify the consumption of the loads in watts for each relays channel. The device will calculate total consumption relative to the time, during which the output of the relays is in the ON state.
39
2
0
OUT–4 LOAD
Power of the Relay 4 load in W. It is possible to specify the consumption of the loads in watts for each relays channel. The device will calculate total consumption relative to the time, during which the output of the relays is in the ON state.
4
1
0
HOUR
This Parameter allows manual adjustment of Time in hours (24 hours).
40
2
0
OUT–5 LOAD
Power of the Relay 5 load in W. It is possible to specify the consumption of the loads in watts for each relays channel. The device will calculate total consumption relative to the time, during which the output of the relays is in the ON state.
41
1
1
TIME MODE OPERATION
This parameter determines the Climate Mode (Heating or Cooling) to which HE-FT01 will switch when the TIME operating mode is selected.
42
2
600
MORNING START TIME
Morning start time for the Temperature Schedules. Format: HHMM. e.g.08:00 should be sent as 0800.
43
2
900
DAY START TIME
Day start time for the Temperature Schedules. Format: HHMM. e.g.08:00 should be sent as 0800.
44
2
1800
EVENING START TIME
Evening start time for the Temperature Schedules. Format: HHMM. e.g.08:00 should be sent as 0800.
45
2
2300
NIGHT START TIME
Night start time for the Temperature Schedules. Format: HHMM. e.g.08:00 should be sent as 0800.
46
2
240
MONDAY MORNING TEMP
Monday Morning temperature, valueX10
47
2
200
MONDAY DAYTIME TEMP
Monday Day temperature, valueX10
48
2
230
MONDAY EVENING TEMP
Monday Evening temperature, valueX10
49
2
180
MONDAY NIGHT TEMP
Monday Night temperature, valueX10
5
1
0
MINUTE
This Parameter allows manual adjustment of the Time in minutes (60 minutes))
50
2
240
TUESDAY MORNING TEMP
Tuesday Morning temperature, valueX10
51
2
200
TUESDAY DAYTIME TEMP
Tuesday Day temperature, valueX10
52
2
230
TUESDAY EVENING TEMP
Tuesday Evening temperature, valueX10
53
2
180
TUESDAY NIGHT TEMP
Tuesday Night temperature, valueX10
54
2
240
WEDNESDAY MORNING TEMP
Wednesday Morning temperature, valueX10
55
2
200
WEDNESDAY DAYTIME TEMP
Wednesday Day temperature, valueX10
56
2
230
WEDNESDAY EVENING TEMP
Wednesday Evening temperature, valueX10
57
2
180
WEDNESDAY NIGHT TEMP
Wednesday Night temperature, valueX10
58
2
240
THURSDAY MORNING TEMP
Thursday Morning temperature, valueX10
59
2
200
THURSDAY DAYTIME TEMP
Thursday Day temperature, valueX10
6
1
0
DEGREE MODE
Degree mode (C/F) Floor and air temperature, as well as Set Point and all Parameters will be indicated in the chosen mode. Factory default value is degrees Celsius (0).
60
2
230
THURSDAY EVENING TEMP
Thursday Evening temperature, valueX10
61
2
180
THURSDAY NIGHT TEMP
Thursday Night temperature, valueX10
62
2
240
FRIDAY MORNING TEMP
Friday Morning temperature, valueX10
63
2
200
FRIDAY DAYTIME TEMP
Friday Day temperature, valueX10
64
2
230
FRIDAY EVENING TEMP
Friday Evening temperature, valueX10
65
2
180
FRIDAY NIGHT TEMP
Friday Night temperature, valueX10
66
2
240
SATURDAY MORNING TEMP
Saturday Morning temperature, valueX10
67
2
200
SATURDAY DAYTIME TEMP
Saturday Day temperature, valueX10
68
2
230
SATURDAY EVENING TEMP
Saturday Evening temperature, valueX10
69
2
180
SATURDAY NIGHT TEMP
Saturday Night temperature, valueX10
7
1
0
AIR TEMP CORRECTION
This Parameter defines the offset value for room air temperature. If the internal air temperature sensor is not correctly calibrated, then manual calibration can be accomplished by adjusting the values up to ±9.5°C (±17°F). This value will be added or subtracted from the internal air temperature sensor reading.
70
2
240
SUNDAY MORNING TEMP
Sunday Morning temperature, valueX10
71
2
200
SUNDAY DAYTIME TEMP
Sunday Day temperature, valueX10
72
2
230
SUNDAY EVENING TEMP
Sunday Evening temperature, valueX10
73
2
180
SUNDAY NIGHT TEMP
Sunday Night temperature, valueX10
8
1
5
TEMP HYSTERESYS
This Parameter defines the hysteresis value for temperature control. The HE-FT01 will stabilize the temperature with the selected hysteresis. For example, if the SET POINT is set for 25°C and HYSTERESIS is set for 0.5°C, the HE-FT01 will change the state to IDLE if the temperature reaches 25.0°C. It will change the state to HEATING if the temperature becomes lower than 24.5°C, and will change the state to COOLING if the temperature rises beyond 25.5°C. The hysteresis value can be changed from 0.2°C to 10.0°C range in Celsius mode, and 0.3°F to 18.0°F in Fahrenheit. The factory-default value is 0.5°C (0.9°F).
9
1
1
AUTO BRIGHTNESS
Display auto-brightness control The HE-FT01 can adjust its display brightness automatically depending on the ambient room brightness.
Application Status
COMMAND_CLASS_APPLICATION_STATUS
Association Group Information V3
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3
Association V2
COMMAND_CLASS_ASSOCIATION_V2
Basic V2
COMMAND_CLASS_BASIC_V2
Clock
COMMAND_CLASS_CLOCK
Configuration V4
COMMAND_CLASS_CONFIGURATION_V4
Device Reset Locally
COMMAND_CLASS_DEVICE_RESET_LOCALLY
Firmware Update Meta-Data V5
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5
Indicator V3
COMMAND_CLASS_INDICATOR_V3
Manufacturer Specific V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
Meter V4
COMMAND_CLASS_METER_V4
Multi-Channel Association V3
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3
Powerlevel
COMMAND_CLASS_POWERLEVEL
Security S0
COMMAND_CLASS_SECURITY
Security S2
COMMAND_CLASS_SECURITY_2
Sensor Multilevel V11
COMMAND_CLASS_SENSOR_MULTILEVEL_V11
Supervision
COMMAND_CLASS_SUPERVISION
Thermostat Fan Mode V4
COMMAND_CLASS_THERMOSTAT_FAN_MODE_V4
Thermostat Fan State V2
COMMAND_CLASS_THERMOSTAT_FAN_STATE_V2
Thermostat Mode V3
COMMAND_CLASS_THERMOSTAT_MODE_V3
Thermostat Operating State
COMMAND_CLASS_THERMOSTAT_OPERATING_STATE
Thermostat Setpoint V3
COMMAND_CLASS_THERMOSTAT_SETPOINT_V3
Transport Service V2
COMMAND_CLASS_TRANSPORT_SERVICE_V2
Version V3
COMMAND_CLASS_VERSION_V3
Z-Wave Plus Info V2
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
Where to find S2 DSK on product
The device DSK and QR code are printed on the HE-HF01 back panel plus on the manual included in the HE- FT01 packaging.
Classic Exclusion
To remove HE-FT01 from a Z-Wave network (exclusion), do the following:

1. Enter “SETTINGS” Mode by pressing and holding the “Climate” button ( ) for three seconds.

2. Scroll menu to “Parameter 15 – nEt” using the “SPEED” button to scroll up, and the “MODE” button to scroll down.

3. The current state of the network will display in the Parameter Value position (bottom left corner). It should display “InC”. Note: If “EcL” is displayed, the HE-FT01 is already Excluded.

4. Start the Exclusion Mode from the gateway/controller.

5. Press the Minus “–” button in the HE-FT01 Parameter 15 to start the Exclusion process.

6. Note that lines will be moving in the Parameter value position (bottom left corner).

7. The Antenna icon should appear in the bottom right corner and “EcL” in the value position if the Exclusion was successful.

8. If the Antenna with signal strength bars icon or “InC” in value position are displayed, repeat the Exclusion process.

Note: If the HE-FT01 has previously been part of a Z-Wave network and has not been Excluded since, Inclusion is not possible without first performing an Exclusion or Factory Reset procedure.

Note: If the HE-FT01 is included in the Z-Wave network the antenna icon will appear in the bottom right corner of the main screen with signal strength bars.

Factory Reset Procedure
By pressing and holding the “MODE” button for 6 seconds, the HE-FT01 will enter Factory Reset Mode, displaying “REs” in the left bottom corner, “y” and “n” in the center. Press the Plus (+) button to revert to factory settings, or the “SPEED” button to cancel.

The factory reset will change all the Parameters to their original factory default values and will also Exclude the device from any Z-Wave network.

Please use Factory Reset only when the primary network controller is missing or otherwise inoperable.
Classic Inclusion
To add HE-FT01 into a Z-Wave network (inclusion), do the following:

1. Enter “SETTINGS” Mode by pressing and holding the “Climate” button for three seconds.

2. Scroll menu to “Parameter 15 – nEt” using the “SPEED” button to scroll up, and the “MODE” button to scroll down.

3. The current state of the network will display in the Parameter Value position (bottom left corner). It should display “EcL”. Note: If “InC” is displayed, the HE-FT01 must first be Excluded from an existing Z-Wave network (see “Removal from a Z-Wave Network” below).

4. Start the Inclusion Mode from the gateway/controller.

5. On the HE-FT01 in Parameter 15, press the Plus “+” key to start the Inclusion process.

6. Note that lines will be moving in the Parameter value position (bottom left corner).

7. The Antenna with signal strength bars icon should appear at the bottom right corner if Inclusion was successful.

8. If the Antenna icon without bars is displayed or “Err” is in the Value position, the HE-FT01 Inclusion was not successful (try repeating steps 4-7).

S2 Authenticated
S2_AUTHENTICATED
S2 Unauthenticated
S2_UNAUTHENTICATED
Firmware Updatable
Indicates whether the firmware can be updated and whether it is done by the consumer or a technician.
Thermostat HVAC Systems Supported
Indicate which HVAC system or systems are supported by the thermostat.
Thermostat Modes
Select the mode(s) supported by the thermostat.
Thermostat Power Source
Select one or more supported power sources for a thermostat.
Switch Type
Describes the type of operator for a switch.
Neutral Wire Required
For electric in-wall/wired switches, indicate whether a neutral wire is required for installation.
Switch Load Capacity Current
The amount of switch load energy the product is rated for in Amps

 

Reviews

Write a review

HELTUN Z-Wave thermostat for fan coil units (White)

HELTUN Z-Wave thermostat for fan coil units (White)

The Heltun thermostat for Fan Coil or fan coil units is a programmable Z-Wave electronic room thermostat for heat / cold. It is designed for recessed mounting in most standard wall boxes. White color