Nombre: Z-Wave Smart Dimmer Socket
Fabricante:Philio
Identificador:PAD02
Número de Certificación Z-Wave:ZC10-17045556
Plataforma Hardware:SD3502
FLiRS:NO
Tipo de Role:Always On Slave
Descripción Corta:PAD02 is an E27(EU)/ E26(US) Edison screw based lamp socket, which provides electrical connection to the E14(EU)/ E12(US) Edison screw based lamps and support it in the lighting fixture. The use of socket allows lamps to be safely and conveniently replaced.
Descripción:PAD02 is an E27(EU)/ E26(US) Edison screw based lamp socket, which provides electrical connection to the E14(EU)/ E12(US) Edison screw based lamps and support it in the lighting fixture. The use of socket allows lamps to be safely and conveniently replaced. You can On/Off the light by pressing the button briefly, or a long pressing to control the brightness of dimmable lightbulb.
This dimmer is a transceiver which is a security enabled device which based on Z-Wave Plus technology. Z-Wave PlusTM enabled devices displaying the Z-Wave PlusTM logo can also be used with it regardless of the manufacturer, and can also be used in other manufacturer’s Z- WaveTM enabled networks. Remote dim level control of the connected light is possible with other manufacturer’s wireless Controller. Since PAD02 supports Security Command Class, it can learn with a Secured enabled controller to fully utilize the device. Its functionality and supported command classes is identical when included as a secure and non-secure device.
Adding to Z- WaveTM Network
In the front casing, there is an on/off button with LED indicator below which is used to switch on and off, dim level, or carries out add, remove, reset or association. When first power is applied, its LED flashes on and off alternately and repeatedly at 0.5 second intervals. It implies that it has not been assigned a node ID and start auto inclusion.
Auto Inclusion
The function of auto inclusion will be executed as long as the dimmer does not have Node ID and just connect the dimmer to main power. Note: Auto inclusion timeout is 2 minute during which the node information of explorer frame will be emitted once every several seconds. Unlike “inclusion” function as shown in the table below, the execution of auto inclusion is free from pressing the On/Off button on the dimmer.
Descargue el manual desde aquí.
Grupo
Max Nodos
Descripción
1
5
Lifeline
The dimmer can be set to send reports to associated Z-Wave devices. It supports one association group with one node support for Grouping 1. For group 1, the dimmer will report ALARM_REPORT 、DEVICE_RESET_LOCALLY_NOTIFICATION and MULTILEVEL_SWITCH_REPORT.
2
5
When the On/Off status changes or the dim level is achieved manually, it will send BASIC_SET command to group 2 nodes to make them unanimous.
Número
Tamaño (Bytes)
Valor por Defecto
Nombre
Descripción
1
1
1
Dimmer Level Report mode
Whenever dimmer on/off state changes, it will send MULTILEVEL_SWITCH_REPORT to the nodes of group1. The default setting is Enable the function.
2
1
1
LED indication mode
1. Show dimmer State:When dimmer is on, LED is on. When dimmer is off, LED is off. The default setting is Show dimmer State.
2. Show Night mode:When dimmer is on, LED is off. When dimmer is off, LED is on.
3. One flash mode : When dimmer on/off state changes, LED will light on one second and then off.
4
1
1
Restore dimmer state
Whenever the AC power return from lost, PAD02 will restore the switch state which could be Dimmer off、Last dimmer state、Dimmer on. The default setting is Last dimmer state.
Basic
COMMAND_CLASS_BASIC
Alarm
COMMAND_CLASS_ALARM
Association Group Info
COMMAND_CLASS_ASSOCIATION_GRP_INFO
Association V2
COMMAND_CLASS_ASSOCIATION_V2
Basic
COMMAND_CLASS_BASIC
Configuration
COMMAND_CLASS_CONFIGURATION
Device Reset Locally
COMMAND_CLASS_DEVICE_RESET_LOCALLY
Firmware Update Meta-Data V2
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
Manufacturer Specific V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
Powerlevel
COMMAND_CLASS_POWERLEVEL
Scene Activation
COMMAND_CLASS_SCENE_ACTIVATION
Scene Actuator Conf
COMMAND_CLASS_SCENE_ACTUATOR_CONF
Security S0
COMMAND_CLASS_SECURITY
Switch Multilevel V2
COMMAND_CLASS_SWITCH_MULTILEVEL_V2
Version V2
COMMAND_CLASS_VERSION_V2
Z-Wave Plus Info V2
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
Factory Reset
Use this procedure only in the event that the primary controller is lost or otherwise inoperable.
1. Pressing Include button of PAD02 three times within 2 seconds will enter inclusion mode.
2. Within 1 second, press Include button of PAD02 again for 5 seconds.
3. IDs are excluded.
Inclusion
1. Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer.
2. Pressing Include button of PAD02 three times within 2 seconds will enter inclusion mode.
Exclusion
1. Put your Z-Wave controller into exclusion mode by following the instructions provided by the controller manufacturer.
2. Pressing Include button of PAD02 three times within 2 seconds will enter exclusion mode.
3. Node ID has been excluded.
Firmware Updatable
Indicates whether the firmware can be updated and whether it is done by the consumer or a technician.
Switch Load Capacity Watts
The amount of switch load energy the product is rated for in Watts
Neutral Wire Required
For electric in-wall/wired switches, indicate whether a neutral wire is required for installation.
Z-Wave Scene Type
Indicates which of the two types of Z-Wave scene command classes are supported. Scenes or Central Scene
Color