Número
Tamaño (Bytes)
Valor por Defecto
Nombre
Descripción
10
4
101968650
Set the alarm time for the Buzzer when the sensor is triggered.
Set the alarm time for the Buzzer when the sensor is triggered.
101
1
3
To set what unsolicited report would be sent to the Lifeline group.
To set what unsolicited report would be sent to the Lifeline group.
111
4
3600
To set the interval time of sending reports in Report group 1
To set the interval time of sending reports in Report group 1.
Note:
1. The unit of interval time is second if USB power.
2. If battery power, the minimum interval time is equal to Wake Up interval set by the Wake Up CC.
135
1
1
To set which sensor report can be sent when the water leak event is triggered and if the receiving device is a non-multichannel device.
To set which sensor report can be sent when the water leak event is triggered and if the receiving device is a non-multichannel device.
136
1
0
When the parameter 0x87 is set to 2 or 3, it can get the sensor probes’ status through this configuration value.
When the parameter 0x87 is set to 2 or 3, it can get the sensor probes’ status through this configuration value.
Note: This parameter is a Get- only parameter.
2
1
0
Enable/Disable waking up for 10 minutes when re-power on (battery mode) the MultiSensor.
Enable/Disable waking up for 10 minutes when re-power on (battery mode) the MultiSensor.
201
2
1
Temperature sensor calibration
Temperature sensor calibration.
Note:
1. High byte is the calibration value. Low byte is the unit (0x00=Celsius, 0x01=Fahrenheit)
2. The calibration value (high byte) contains one decimal point. E.g. if the value is set to 20 (0x1400), the calibration value is 2.0 ℃ (EU/AU version) or if the value is set to 20 (0x1401), the calibration value is 2.0 ℉(US version)
3. The calibration value (high byte) = standard value - measure value.
E.g. If measure value =25.3℃ and the standard value = 23.2℃, so the calibration value= 23.2℃ - 25.3℃= -2.1℃ (0xEB).
If the measure value =30.1℃ and the standard value = 33.2℃, so the calibration value= 33.2℃ - 30.1℃=3.1℃ (0x1F).
252
1
0
Enable/disable all configuration parameters to be locked
Enable/disable all configuration parameters to be locked.
255
4
0
Reset to factory defaults.
Reset to factory defaults.
39
1
20
Configure the default low battery value.
Configure the default low battery value. When the current battery level is lower than this value, it will send out the low battery alarm.
48
1
0
Enable/disable the sensor report
Enable/disable the sensor report
49
4
68157696
Set the upper limit value (overheat).
Set the upper limit value (overheat).
50
4
20971776
Set the lower limit value (under heat)
Set the lower limit value (under heat)
57
2
5121
Set the recover limit value of temperature sensor.
Note:
1. When the current measurement <= (Upper limit – Recover limit), the upper limit report is enabled and then it would send out a sensor report when the next measurement is more than the upper limit. After that the upper limit report would be disabled again until the measurement <= (Upper limit – Recover limit).
2. When the current measurement >= (Lower limit + Recover limit), the lower limit report is enabled and then it would send out a sensor report when the next measurement is less than the lower limit. After that the lower limit report would be disabled again until the measurement >= (Lower limit + Recover limit).
3. High byte is the recover limit value. Low byte is the unit (0x01=Celsius, 0x02=Fahrenheit).
64
1
1
Set the default unit of the automatic temperature report in parameter 101-103.
Set the default unit of the automatic temperature report in parameter 101-103.
8
1
30
Set the timeout of awake after the Wake Up CC is sent out..
Set the timeout of awake after the Wake Up CC is sent out..
84
1
0
Get the state of tilt sensor
Get the state of tilt sensor.
Note: this is a Get-only parameter.
86
1
1
Enable/ disable the buzzer.
Enable/ disable the buzzer.
87
4
55
To set which sensor is triggered the buzzer will alarm.
To set which sensor is triggered the buzzer will alarm.
88
1
0
To set which value of the Basic Set will be sent to the associated nodes in association Group 3 when the Sensor probe 1 is triggered.
To set which value of the Basic Set will be sent to the associated nodes in association Group 3 when the Sensor probe 1 is triggered.
89
1
0
To set which value of the Basic Set will be sent to the associated nodes in association Group 4 when the Sensor probe 2 is triggered.
To set which value of the Basic Set will be sent to the associated nodes in association Group 4 when the Sensor probe 2 is triggered.
9
2
0
Report the current power mode and the product state for battery power mode
Report the current power mode and the product state for battery power mode.
Note: this parameter cannot be used as Set usage.
94
1
0
To set which power source level is reported via the Battery CC.
To set which power source level is reported via the Battery CC.