Produtos visualizados





Confianza Online


domoticalia.es/es/ Reviews with ekomi.es

ZOOZ Outdoor Motion Sensor

ZSE70

Novo

Em estoque

49,99 €

Características tecnicas

Tecnologia Domótica Z-Wave Long Range

Informação alargada da Z-Wave (Inglês)

Nome: Outdoor Motion Sensor
Fabricante:Zooz
Identificador:ZSE70 800LR
Número de Certificação Z-Wave :ZC14-24110480
Plataforma de Hardware :EFR32ZG23A
FLiRS:Não
Tipo de Role :Reporting Sleeping End Node
Descrição breve :The Zooz 800 Series Outdoor Motion Sensor offers reliable motion, temperature, and light detection with Z-Wave Long Range, ideal for hands-free automation and enhanced outdoor security.
Descrição :The Zooz 800 Series Outdoor Motion Sensor offers reliable motion, temperature, and light detection with Z-Wave Long Range, ideal for hands-free automation and enhanced outdoor security.
Grupo
Nodos máximos
Descrição
1
5
2
5
Número
Tamanho (Bytes)
Valor por defeito
Nome
Descrição
1
1
6
Motion sensitivity
Motion sensitivity
10
2
10
Light Threshold Check Time
Light Threshold Check Time
11
1
2
Battery threshold
Battery threshold
12
1
1
Temperature threshold
Temperature threshold
13
2
50
Light threshold
Light threshold
14
1
100
Temperature calibrate offset
Temperature calibrate offset
15
1
100
Light calibrate offset
Light calibrate offset
16
2
0
Dusk to Dawn
Dusk to Dawn
17
2
0
Automatic report interval time for temp
Automatic report interval time for temp
18
2
0
Automatic report interval time for light
Automatic report interval time for light
2
2
30
Motion untrigger time
Motion untrigger time
3
1
7
Motion group control
Motion group control
4
2
65280
Motion Group Value Setting
Motion Group Value Setting
5
1
1
Temperature report scale
Temperature report scale
6
1
1
LED activity
LED activity
7
1
10
Low battery threshold
Low battery threshold
8
2
4
Battery power checking interval
Battery power checking interval
9
2
30
Temperature Threshold Check Time
Temperature Threshold Check Time
Application Status
COMMAND_CLASS_APPLICATION_STATUS
Association Group Information (AGI) V3
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3
Association V2
COMMAND_CLASS_ASSOCIATION_V2
Battery
COMMAND_CLASS_BATTERY
Configuration V4
COMMAND_CLASS_CONFIGURATION_V4
Device Reset Locally
COMMAND_CLASS_DEVICE_RESET_LOCALLY
Firmware Update Meta Data V5
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5
Indicator V3
COMMAND_CLASS_INDICATOR_V3
Manufacturer Specific V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
Multi Channel Association V3
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3
Multilevel Sensor V11
COMMAND_CLASS_SENSOR_MULTILEVEL_V11
Notification V8
COMMAND_CLASS_NOTIFICATION_V8
Powerlevel
COMMAND_CLASS_POWERLEVEL
Security 0
COMMAND_CLASS_SECURITY
Security 2
COMMAND_CLASS_SECURITY_2
Supervision
COMMAND_CLASS_SUPERVISION
Transport Service V2
COMMAND_CLASS_TRANSPORT_SERVICE_V2
Version V3
COMMAND_CLASS_VERSION_V3
Wake Up V2
COMMAND_CLASS_WAKE_UP_V2
Z-Wave Plus Info V2
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
Where to find S2 DSK on product
If you’re using an S2 hub, it will ask you to enter the

DSK key or scan the QR code printed on the sticker on

the side of the cover to complete SmartStart inclusion.
Classic Inclusion
Put your Z-Wave® hub into inclusion mode and click

the Z-Wave® button 3 times as quickly as possible. The

LED indicator will start blinking to confirm inclusion

mode and turn off once inclusion is completed.
Classic Exclusion
1. Bring the sensor within direct range of your Z-Wave®

gateway (hub).

2. Put the Z-Wave® hub into exclusion mode (not sure

how to do that? ask@getzooz.com).

3. Click the Z-Wave® button 3 times quickly.

4. Your hub will confirm exclusion and the sensor will

disappear from your controller''s device list.
Wake-Up Procedure
The sensor’s wake-up interval is set to 4 hours by default to

save battery life. Use the Wake Up Command Class to adjust

the interval (in seconds, working in 3600s intervals, with 3600

as min and 86400 as max values). Click the Z-Wave® button

once to wake the sensor up manually. During wake-up, the

sensor turns the Z-Wave® radio for 10 seconds to receive

communication from the hub. Long wake-up interval will not

affect how o
Factory Reset Procedure
When your network’s primary controller is missing or

otherwise inoperable, you may need to reset the device

to factory settings manually. In order to complete the

process, make sure the sensor is powered, then hold

the Z-Wave® button down for at least 10 seconds.

The LED indicator will start flashing blue and turn solid

blue for a couple of seconds to indicate successful reset.

NOTE: All previously recorded activity and custom settings will be

erased from the device’s memory.
S2 Authenticated
S2_AUTHENTICATED
S2 Unauthenticated
S2_UNAUTHENTICATED
Battery Quantity
Enter the number of batteries of the designated type that the product uses.
Battery Type
Enter the type (e.g. AA, CR2032, AAA) of the battery/batteries that the product uses.
Color
If the product is only available in one color, pick the color from the list.
Firmware Updatable
Indicates whether the firmware can be updated and whether it is done by the consumer or a technician.
Outdoor Use
Product is suitable for use outdoors.

 

Avaliações

Escrever uma avaliação

ZOOZ Outdoor Motion Sensor

ZOOZ Outdoor Motion Sensor

7 outros produtos na mesma categoria: