Nome: Heatit Z-Smoke Detector 230V
Fabricante:Heatit controls
Identificador:4512689
Número de Certificação Z-Wave :ZC10-20076952
Plataforma de Hardware :ZM5202
FLiRS:Não
Tipo de Role :Always On Slave
Descrição breve :Z-Smoke Detector 230V is a mini-sized wireless smoke detector with built-in PIR motion sensor, temperature sensor and emergency light (optional).
Descrição :The Z-Smoke Detector is a wirelessly operated photo-electronic Smoke Detector designed to operate with any Z-Wave enabled controller devices; it also features smoke detecting, temperature sensing and IR detection. The Smoke Detector’s alarm situations, battery condition, operating conditions, supervisory data and general fault information are sent to the Z-Wave Gateway/Control Panel wirelessly. The device is also serially connected with other sensors in the Z-Wave gateway to serve as an extra siren.
Descarregue o manual a partir de aqui.
Grupo
Nodos máximos
Descrição
1
1
Group 1 for “LifeLine”: (maximum node: one)
Battery CC (COMMAND_CLASS_BATTERY)
Notification CC,V8 (COMMAND_CLASS_NOTIFICATION)
SensorMutilevel CC, V11 (COMMAND_CLASS_SENSOR_MULTILEVEL)
Device Reset Locally CC (COMMAND_CLASS_DEVICE_RESET_LOCALLY)
2
1
Basic CC (COMMAND_CLASS_BASIC)
#.When the Smoke Detector is active, it will send Basic Set (0xFF) in Group 2.
#.When the Smoke Detector is restored, it will send Basic Set (0x00) in Group 2.
Número
Tamanho (Bytes)
Valor por defeito
Nome
Descrição
Basic V2
COMMAND_CLASS_BASIC_V2
Association Group Info
COMMAND_CLASS_ASSOCIATION_GRP_INFO
Association V2
COMMAND_CLASS_ASSOCIATION_V2
Battery
COMMAND_CLASS_BATTERY
Device Reset Locally
COMMAND_CLASS_DEVICE_RESET_LOCALLY
Firmware Update Meta-Data V4
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
Manufacturer Specific V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
Multi-Channel Association V3
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3
Notification V8
COMMAND_CLASS_NOTIFICATION_V8
Powerlevel
COMMAND_CLASS_POWERLEVEL
Security S2
COMMAND_CLASS_SECURITY_2
Sensor Multilevel V11
COMMAND_CLASS_SENSOR_MULTILEVEL_V11
Supervision
COMMAND_CLASS_SUPERVISION
Transport Service V2
COMMAND_CLASS_TRANSPORT_SERVICE_V2
Version V3
COMMAND_CLASS_VERSION_V3
Z-Wave Plus Info V2
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
Classic Inclusion
1. Before you start, find the circuit breaker or fuse box.
2. Once you have found it, open the door and turn off the main power switch. Step
3. Two Wago 221 Splicing Connectors are provided. Take out one connector. Pull the lever up and insert the white wire.
4. Push the lever back down. The transparent housing allows you to check if the wire is connected properly. Make sure the wire is tightly held in place before you proceed.
5. Repeat Step 3 and Step 4 to insert the black wire. Inserting the two wires to the same side (right), as shown below, of the two connectors provides an easier installation in the following steps.
7. Put the Z-Wave gateway or control panel into Inclusion or Learning mode (please refer to the Z-Wave gateway or control panel manual).
8. Within 1.5 seconds, press the Function button 3 times. The Smoke Detector will emit a 2-tone beep and the LED will turn on for ~2 seconds. Refer to the operation manual of the Z-Wave gateway or control panel to complete the learn-in process.
6. Insert the AC wires to the two connectors respectively, as shown below. Use a pair of tweezers to turn the Battery Switch to ON position (left side), the rechargeable battery will begin to charge.
Classic Exclusion
1. Put the Z-Wave gateway or control panel into Exclusion mode (please refer to the Z-Wave gateway or control panel manual).
2. Within 1.5 seconds, press the Function button 3 times and the Smoke Detector will be removed from the Z-Wave network.
Wake-Up Procedure
Role Type Always on Slave
no Wake-Up Procedure
Factory Reset Procedure
(Only use factory reset when network Control Panel/Gateway is missing or inoperable)
1. Remove the batteries of the Smoke Detector first.
2. Press and hold the Function button. While holding the Function button, power on the Smoke Detector by re-inserting the batteries, wait for 20 seconds to factory reset.
S2 Unauthenticated
S2_UNAUTHENTICATED
Firmware Updatable
Indicates whether the firmware can be updated and whether it is done by the consumer or a technician.
Battery Type
Enter the type (e.g. AA, CR2032, AAA) of the battery/batteries that the product uses.
Battery Quantity
Enter the number of batteries of the designated type that the product uses.