Nome: Door/Window Sensor 7
Fabricante:Aeotec
Identificador:ZWA008-C
Número de Certificação Z-Wave :ZC10-19066568
Plataforma de Hardware :ZM5101
FLiRS:Não
Tipo de Role :Reporting Sleeping Slave
Descrição breve :Z-Wave Door/ Window Sensor 7.
Descrição :Aeotec Door/ Window Sensor 7 is a small window position sensor for your smart home, it monitors window and their exact opening position and lets your know when a window is tilted or completely opened. It also supports connecting external binary sensors through the dry binary contact of the Door/ Window sensor.
Descarregue o manual a partir de aqui.
Grupo
Nodos máximos
Descrição
2
5
Control devices when magnet or external dry contacts trips
3
5
Sends our alarm message when magnet controlled or external dry sensor trips.
4
5
Sends alarm messages when tamper is tripped
Número
Tamanho (Bytes)
Valor por defeito
Nome
Descrição
1
1
0
Sensor Operation Mode
This parameter defines if the internal magnet sensor or the external terminal input is detected and used to issue alarm notification. There is always one input active only. The other sensor input the deactivated.
10
2
0
Time Delay of ‘Off‘ command frame
Off command is sent after a delay defined in this parameter.
11
2
0
Delay of Tamper Alarm Cancellation
Time a tamper alarm is delayed.
12
1
1
Reporting Tamper Alarm Cancellation
This parameter defines if the alarm cancellation event is reported.
13
1
0
Central Scene Event Functionality
This parameter enables/disables the central scene function.
14
1
1
Tilt Sensor Functionality
This parameter enables/disables the tilt function.
2
1
0
Sensor State Polarity
This parameter defines the polarity of the magnet sensor.
3
1
7
Visual LED Indications
This parameter defines when the red LED will indicate events. Disabling all indications may extend battery life.
4
1
0
Range Test after double click
Allows to enable the activation of a Z-Wave range test with double clicking the tamper switch.
5
1
0
2nd Association Group Trigger
his parameter defines the status of the magnet switch that causes sending a BASIC command to all devices of Association Group 2.
6
1
2
Command Sent to Devices of Association Group 2
This parameter defines which commands is sent to 2nd Association Group
7
1
-1
BASIC command value sent to 2nd Association Group on ‘On‘ event
This is the BASIC command value sent in case of ‘On‘ event.
8
1
0
BASIC command value sent to 2nd Association Group on ‘Off‘ event
This is the BASIC command value sent in case of ‘Off‘ event.
9
2
0
Time Delay of ‘Off‘ command frame
Off command is sent after a delay defined in this parameter.
Association Group Info
COMMAND_CLASS_ASSOCIATION_GRP_INFO
Association V2
COMMAND_CLASS_ASSOCIATION_V2
Battery
COMMAND_CLASS_BATTERY
Central Scene V3
COMMAND_CLASS_CENTRAL_SCENE_V3
Configuration
COMMAND_CLASS_CONFIGURATION
Device Reset Locally
COMMAND_CLASS_DEVICE_RESET_LOCALLY
Firmware Update Meta-Data V4
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
Manufacturer Specific V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
Multi-Channel Association V3
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3
Notification V8
COMMAND_CLASS_NOTIFICATION_V8
Powerlevel
COMMAND_CLASS_POWERLEVEL
Security S2
COMMAND_CLASS_SECURITY_2
Sensor Binary V2
COMMAND_CLASS_SENSOR_BINARY_V2
Supervision
COMMAND_CLASS_SUPERVISION
Transport Service V2
COMMAND_CLASS_TRANSPORT_SERVICE_V2
Version V3
COMMAND_CLASS_VERSION_V3
Wake Up V2
COMMAND_CLASS_WAKE_UP_V2
Z-Wave Plus Info V2
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
Factory Reset
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
Once Cover is removed and tamper switch is tripped, push the tamper for 5 seconds until red LED blinks. Then release tamper and push it again for 5 seconds until LED blinks.
Inclusion
Tripple clicking the tamper button includes (adds) the device.
Exclusion
Tripple clicking the tamper button excludes (removes) the device.
Device Wake-Up
A single click on the tamper button will wakeup the device.
Additional Special Features
It supports connecting external sensor. E.g. Dry Contact Sensor, Water Sensor probes.
S2 Unauthenticated
S2_UNAUTHENTICATED
Battery Quantity
Enter the number of batteries of the designated type that the product uses.
Battery Type
Enter the type (e.g. AA, CR2032, AAA) of the battery/batteries that the product uses.
Color
If the product is only available in one color, pick the color from the list.
Firmware Updatable
Indicates whether the firmware can be updated and whether it is done by the consumer or a technician.
Sensors
Sensor types supported by the product.
Supported Notification Types
Select the Notification Types that the product handles (controllers), or sends (slaves).