Nome: Outdoor Solar Siren
Fabricante:Popp
Identificador:POPE005107
Número de Certificação Z-Wave :ZC10-16125334
Plataforma de Hardware :ZM5202
FLiRS:Sim
Tipo de Role :Listening Sleeping Slave
Descrição breve :Outdoor Solar operated Siren
Descrição :This solar powered outdoor siren can be used without any additional power supply or batteries. It can be installed on any place on the outside of the house and can be controlled using Z-Wave. The device will issue a very loud sound (105 dBm) and in parallel some stroboscope light as well. The siren is self-protecting. Removing the main device from the mounting unit immediately starts the siren and also reports the tamper attempt to the Z-Wave central controller. All communication between the Z-Wave controller and the siren is encrypted and secured to protect against manipulation. Thanks to the large solar panel the siren can be mounted on nearly every place outside the house, with direct or indirect sun light. The siren is maintenance-free and water-proofed (IP56). The average solar energy of one day keeps the device alive for up to 50 days (without using the siren). Additionally an internal temperature sensor reports the temperature inside the siren’s enclosure.
Descarregue o manual a partir de aqui.
Grupo
Nodos máximos
Descrição
Número
Tamanho (Bytes)
Valor por defeito
Nome
Descrição
1
1
0
Siren Tamper Mode
Sets the tamper triggering mode when removed from the holder
2
1
0
Temperature Adjustment
Temperature correction. The given value changes the displayed temperature by 0.1K
3
1
10
Send unsolicited Temperature Report
Temperature Threshold to send unsolicited Temperature Update
4
2
15
Send unsolicited Temperature Report periodically
If the value is set, after N wake up number (measurement is every 4 minutes) the temperature report will be sent. By default it is 15 = every 1 hour
5
1
2
Siren Mode
Determines how the Siren shall react on alarm
6
1
5
Auto Off
If the value is set, the siren will be switched off automatically after a defined alarm time in Minutes.
Association Group Info
COMMAND_CLASS_ASSOCIATION_GRP_INFO
Association V2
COMMAND_CLASS_ASSOCIATION_V2
Basic
COMMAND_CLASS_BASIC
Battery
COMMAND_CLASS_BATTERY
Configuration
COMMAND_CLASS_CONFIGURATION
Device Reset Locally
COMMAND_CLASS_DEVICE_RESET_LOCALLY
Firmware Update Meta-Data V3
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V3
Manufacturer Specific V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
Notification V5
COMMAND_CLASS_NOTIFICATION_V5
Powerlevel
COMMAND_CLASS_POWERLEVEL
Security S0
COMMAND_CLASS_SECURITY
Sensor Binary V2
COMMAND_CLASS_SENSOR_BINARY_V2
Sensor Multilevel V5
COMMAND_CLASS_SENSOR_MULTILEVEL_V5
Switch Binary
COMMAND_CLASS_SWITCH_BINARY
Version V2
COMMAND_CLASS_VERSION_V2
Z-Wave Plus Info V2
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
Exclusion
1. Open the case and turn on the power switch 2. Remove the metal mounting plate from the device. 3. Turn your controller into exclusion mode with a short single click on the internal inclusion button.
Inclusion
1. Open the case and turn on the power switch 2. Remove the metal mounting plate from the device. 3. Turn your controller into inclusion mode with a short single click on the internal inclusion button.
Factory Reset
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
To reset the device keep the inclusion button pushed for 10 seconds. After 5 seconds the LED starts flashing and after another 5 seconds there is a short beep signaling the successful reset back to factory defaults. Use this procedure only when the network primary controller is missing or otherwise inoperable.
Color
If the product is only available in one color, pick the color from the list.
Outdoor Use
Product is suitable for use outdoors.