Nome: SSR 303 (Single Channel On/Off Power switch)
Fabricante:Secure Controls (UK)
Identificador:MAX10Z-384
Número de Certificação Z-Wave :ZC10-16075134
Plataforma de Hardware :ZM5202
FLiRS:Não
Tipo de Role :Always On Slave
Descrição breve :The SSR 303 is a single channel relay/switch, it forms part of central heating control system, it can be operated by any third party controllers/Thermostat using ‘Binary Switch CC’ commands.
Descrição :The SSR 303 is a single channel relay/switch, it forms part of central heating control system, it can be operated by any third party controllers/Thermostat using ‘Binary Switch CC’ commands.
SSR 303 will act as a repeater once added into the Z- Wave network, providing an alternative communication route for units which otherwise would not be within communication distance of each other.
SSR 303 has a fail-safe mode where by the relay is turned OFF if another 'Thermostat Mode SET' command has not been received within 60 minutes.
Descarregue o manual a partir de aqui.
Grupo
Nodos máximos
Descrição
1
4
Z-Wave Plus Lifeline group, SSR 303 will send unsolicited SWITCH BINARY REPORT to lifeline group.
Número
Tamanho (Bytes)
Valor por defeito
Nome
Descrição
Inclusion
STEP 1: Ensure the Network LED is flashing on the SSR 303, if not follow ‘Exclusion’ steps first.
STEP 2: Put the 3rd party controller into inclusion mode.
STEP 3: Press and hold the network button on the SSR 303 until the ‘ON’ LED’s start flashing.
The SSR 303 has been added onto the network when the ‘OFF’ LED goes solid red.
NOTE: If the ON LED does not flash then the add process has been unsuccessful.
Exclusion
STEP 1: Put the 3rd party controller into exclusion mode.
STEP 2: Press and hold the network button on the SSR 303.
The SSR 303 has been removed from the network when the Network LED starts flashing.
NOTE: If the Network LED does not flash the remove process has been unsuccessful.
Factory Reset
""Please use this procedure only when the primary controller is missing or otherwise inoperable.""
Follow ‘Exclusion’ steps.
Additional Special Features
SSR 303 has a fail-safe mode where by the relay is turned OFF if another 'Thermostat Mode SET' command has not been received within 60 minutes.
Color
If the product is only available in one color, pick the color from the list.
IP (Ingress Protection) Rated
Product is suitable for Outdoor use and is waterproof under an IP (Ingress Protection) rating system.
Electric Load Type
Select the electric load type(s) supported by the device.
Switch Load Capacity Current
The amount of switch load energy the product is rated for in Amps
Neutral Wire Required
For electric in-wall/wired switches, indicate whether a neutral wire is required for installation.